The DOI matches its Crossref record.
An Integrated Microfluidic System for Reaction, High-Sensitivity Detection, and Sorting of Fluorescent Cells and Particles
Abstract
Presented is a novel approach for an integrated micro total analysis system (microTAS) based on a microfluidic on-chip device that supports ultrasensitive confocal detection of fluorescent cells and particles and subsequently allows for their precise sorting in the fluid phase with respect to spectroscopic properties, such as brightness and color. The hybrid silicone elastomer/glass chip first comprises a branched channel system to initiate fluid mixing and to hydrodynamically focus the sample solution down to a thin flow layer, matching the size of the confocal detection volume placed at that position and, thus, providing a high detection efficiency. In the subsequent on-chip module, the dispersed cells or particles can be sorted into two different output channels. The sorting process is realized by a perpendicular deflection stream that can be switched electrokinetically. The performance of the automated sorting routine is demonstrated by precise partition of a mixture of differently colored fluorescent beads. Moreover, the specifically branched channel geometry allows for direct implementation of reaction steps prior to detection and sorting, which is demonstrated by inducing a selective recognition reaction between the fluorescent protein R-phycoerythrin and a mixture of live bacterial cells exhibiting or lacking the respective surface antigens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Self-citationWyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Laser‐Induced Release of Encapsulated Materials inside Living Cells
Skirtach, A. G., Muñoz Javier, A., Kreft, O., Köhler, K., Piera Alberola, A., Möhwald, H., Parak, W. J., & Sukhorukov, G. B. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200504599 · Cited by 492
Metadata
- Authors
- Dittrich, P. S., & Schwille, P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-09-16
- Volume
- 75
- Issue
- 21
- Pages
- 5767-5774
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2045344646
- Cited by
- 232
- References
- 0
- FWCI
- 16.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Integrated Microfluidic System for Reaction, High-Sensitivity Detection, and Sorting of Fluorescent Cells and Particles. https://app.cochat.ai/papers/10.1021/ac034568c
- The paper
- Dittrich, P. S., & Schwille, P. (2003). An Integrated Microfluidic System for Reaction, High-Sensitivity Detection, and Sorting of Fluorescent Cells and Particles. Analytical Chemistry. https://doi.org/10.1021/ac034568c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.