The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Quantification of Halide in Ionic Liquids Using Ion Chromatography
Abstract
The determination of chloride impurities in ionic liquids using ion chromatography is described. A wide range of cation-anion combinations may be analyzed using ion chromatography, including water-immiscible ionic liquids. For all ionic liquids studied, the limit of quantification for chloride was found to be below 8 ppm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of chloride, water, and organic solvents on the physical properties of ionic liquids
Seddon, K. R., Stark, A., & Torres, M.-J. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072122275 · Cited by 2,293
Cited by
Pârvulescu, V. I., & Hardacre, C. (2007) · Chemical Reviews · doi:10.1021/cr050948h · Cited by 2,377
Self-citationPredicting physical properties of ionic liquids
Deetlefs, M., Seddon, K. R., & Shara, M. (2006) · Phys. Chem. Chem. Phys. · doi:10.1039/b513453f · Cited by 411
Self-citationHu, S., Zhang, Z., Zhou, Y., Han, B., Fan, H., Li, W., Song, J., & Xie, Y. (2008) · Green Chemistry · doi:10.1039/b810392e · Cited by 332
Assessing the greenness of some typical laboratory ionic liquid preparations
Deetlefs, M., & Seddon, K. R. (2010) · Green Chem. · doi:10.1039/b915049h · Cited by 280
Self-citation
Metadata
- Authors
- Villagrán, C., Deetlefs, M., Pitner, W. R., & Hardacre, C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-03-05
- Volume
- 76
- Issue
- 7
- Pages
- 2118-2123
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2040062275
- Cited by
- 241
- References
- 1
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.