The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Solvent Bar Microextraction
Abstract
In this work, a new and simple microextraction method termed solvent bar microextraction (SBME) was developed. In this method, the organic extractant solvent (1-octanol) was confined within a short length of a hollow fiber membrane (sealed at both ends) that was placed in a stirred aqueous sample solution. Tumbling of the extraction device within the sample solution facilitated extraction. Pentachlorobenzene (PCB) and hexachlorobenzene (HCB) were used as model compounds to investigate the extraction performance. Analysis was carried out by gas chromatography/electron capture detection. This new method provided very high enrichment (approximately 110-fold for PCB and approximately 70-fold for HCB) in 10 min and good reproducibility (<4%, n = 6). Since the hollow fiber membrane was sealed, it could be used for extraction from "dirty" samples, such soil slurries. This novel microextraction method was compared with single-drop microextraction and static hollow fiber membrane microextraction in which the extractant solvent was also held within a hollow fiber but with the latter fixed to a syringe needle (i.e., there was no tumbling effect). Comparison between SBME and conventional solid-phase microextraction in a soil slurry sample was also investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Cited by
Leong, M.-I., & Huang, S.-D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.09.111 · Cited by 413
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Liquid-phase microextraction – The different principles and configurations
Yamini, Y., Rezazadeh, M., & Seidi, S. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.06.010 · Cited by 309
Critical overview of selected contemporary sample preparation techniques
Ramos, L. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.11.011 · Cited by 280
Recent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Metadata
- Authors
- Jiang, X., & Lee, H. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-08-06
- Volume
- 76
- Issue
- 18
- Pages
- 5591-5596
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1994388891
- Cited by
- 217
- References
- 1
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.