The DOI matches its Crossref record.
Peer Reviewed: Thermal Lens Microscopy and Microchip Chemistry
Open accessAbstract
Thermal Lens Microscopy and Microchip Chemistry hermal lens microscopy (TLM) is very sensitive to nonluminescent analytes in liquids and in or on solid matrixes with detection limits at the zeptomole (10 -21 ) to yoctomole (10 -24 ) levels under optimal conditions (1-3).However, the selectivity of TLM is very poor because the heat emitted from different analytes makes them indistinguishable from one another.On the other hand, microchips can separate analyte species with very small volumes, but they lack the highly sensitive detectors needed for the separated analytes.The absolute amount of 1 nM of analyte in 1 µm 3 (1 f L) is 10 -24 mol, which is the sub-singlemolecule level.Therefore, combining TLM with a microchip mitigates the problems of each method and provides a powerful analytical tool.We have developed TLM as a novel laser microspectrometry method and a general-purpose integration method for chemical systems on microchips (3, 4).In this article, we will explain the principles and basic characteristics of TLM, introduce applications of TLM and microchips, and describe some advanced functional TLM techniques. Principles and equipmentTLM is performed with a laser microscope in which the signal-generation mechanism is the thermal lens effect (TLE; 1, 2).Two coaxial laser beams are introduced into a liquid sample under an optical microscope (Figure 1a).The blue beam is an excitation beam, the wavelength of which is selected to coincide with an absorption band of the analyte.The red beam is a probe beam, the wavelength
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Scaling and the design of miniaturized chemical-analysis systems
Janasek, D., Franzke, J., & Manz, A. (2006) · Nature · doi:10.1038/nature05059 · Cited by 716
Recent advances in flow injection analysis
Trojanowicz, M., & Kołacińska, K. (2016) · The Analyst · doi:10.1039/c5an02522b · Cited by 202
Metadata
- Authors
- Kitamori, T., Tokeshi, M., Hibara, A., & Sato, K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-02-01
- Volume
- 76
- Issue
- 3
- Pages
- 52 A-60 A
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2018911825
- Cited by
- 206
- References
- 0
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Peer Reviewed: Thermal Lens Microscopy and Microchip Chemistry. https://app.cochat.ai/papers/10.1021/ac041508d
- The paper
- Kitamori, T., Tokeshi, M., Hibara, A., & Sato, K. (2004). Peer Reviewed: Thermal Lens Microscopy and Microchip Chemistry. Analytical Chemistry. https://doi.org/10.1021/ac041508d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.