The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Real-Time Surface Plasmon Resonance Imaging Measurements for the Multiplexed Determination of Protein Adsorption/Desorption Kinetics and Surface Enzymatic Reactions on Peptide Microarrays
Abstract
The kinetics of protein adsorption/desorption onto peptide microarrays was studied using real-time surface plasmon resonance (SPR) imaging. S protein binding interactions were examined using an array composed of five different peptides: N terminal and C terminal immobilized wild-type S peptide (S1 and S2), an alternate binding sequence derived by phage display (LB2), an NVOC-protected S peptide, and a FLAG peptide control sequence (F). Kinetic measurements of the S protein-S1 peptide interaction were analyzed to determine a desorption rate constant (k(d)) of 1.1 (+/-0.08) x 10(-2) s(-1), an adsorption rate constant (k(a)) of 1.9 (+/-0.05) x 10(5) M(-1) s(-1), and an equilibrium adsorption constant (K(Ads)) of 1.7 (+/-0.08) x 10(7) M(-1). SPR imaging equilibrium measurements of S protein to S1 peptide were performed to independently confirm the kinetically determined value of K(Ads). Rate constants for the S2 and LB2 peptides on the array were measured as follows: 1.6 (+/-0.04) x 10(5) M(-1) s(-1) (k(a)) and 1.1 (+/-0.07) x 10(-2) s(-1) (k(d)) for S2, 1.2 (+/-0.05) x 10(5) M(-1) s(-1) (k(a)) and 1.1 (+/-0.03) x 10(-2) s(-1) (k(d)) for LB2. In addition to S protein adsorption/desorption, real-time SPR imaging of peptide arrays was applied to study the surface enzymatic activities of the protease factor Xa. Enzymatic cleavage of the substrate peptide (P1) was shown to follow first-order kinetics and proceed at a rate 10 times faster than that of the mutant peptide (P2), with cleavage velocities of 5.6 (+/-0.3) x 10(-4) s(-1) for P1 and 5.7 (+/-0.3) x 10(-5) s(-1) for P2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaudhury, M. K., & Whitesides, G. M. (1991) · Langmuir · doi:10.1021/la00053a033 · Cited by 658
Cited by
Surface Plasmon Resonance: A Versatile Technique for Biosensor Applications
Nguyen, H., Park, J., Kang, S., & Kim, M. (2015) · Sensors · doi:10.3390/s150510481 · Cited by 1,357
SHANKARAN, D., GOBI, K., & MIURA, N. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.09.014 · Cited by 607
Metadata
- Authors
- Wegner, G. J., Wark, A. W., Lee, H. J., Codner, E., Saeki, T., Fang, S., & Corn, R. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-08-27
- Volume
- 76
- Issue
- 19
- Pages
- 5677-5684
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2075229839
- Cited by
- 196
- References
- 1
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.