Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Chromatographic Separation and Multicollection-ICPMS Analysis of Iron. Investigating Mass-Dependent and -Independent Isotope Effects

Dauphas, Nicolas, Janney, Philip E., Mendybaev, Ruslan A., Wadhwa, Meenakshi, Richter, Frank M., Davis, Andrew M., van Zuilen, Mark, Hines, Rebekah, Foley, C. Nicole·2004·Analytical Chemistry

Abstract

A procedure was developed that allows precise determination of Fe isotopic composition. Purification of Fe was achieved by ion chromatography on AG1-X8 strongly basic anion-exchange resin. No isotopic fractionation is associated with column chemistry within 0.02 per thousand /amu at 2sigma. The isotopic composition was measured with a Micromass IsoProbe multicollection inductively coupled plasma hexapole mass spectrometer. The Fe isotopic composition of the Orgueil CI1 carbonaceous chondrite, which best approximates the solar composition, is indistinguishable from that of IRMM-014 (-0.005 +/- 0.017 per thousand /amu). The IRMM-014 reference material is therefore used for normalization of the isotopic ratios. The protocol for analyzing mass-dependent variations is validated by measuring geostandards (IF-G, DTS-2, BCR-2, AGV-2) and heavily fractionated Fe left after vacuum evaporation of molten wüstite (FeO) and solar (MgO-Al(2)O(3)-SiO(2)-CaO-FeO in chondritic proportions) compositions. It is shown that the isotopic composition of Fe during evaporation of FeO follows a Rayleigh distillation with a fractionation factor alpha equal to (m(1)/m(2)()1/2), where m(1) and m(2) are the masses of the considered isotopes. This agrees with earlier measurements and theoretical expectations. The isotopic composition of Fe left after vacuum evaporation of solar composition also follows a Rayleigh distillation but with a fractionation factor (1.013 22 +/- 0.000 67 for the (56)Fe/(54)Fe ratio) that is lower than the square root of the masses (1.018 35). The protocol for analyzing mass-independent variations is validated by measuring terrestrial rocks that are not expected to show departure from mass-dependent fractionation. After internal normalization of the (57)Fe/(54)Fe ratio, the isotopic composition of Fe can be measured accurately with precisions of 0.2epsilon and 0.5epsilon at 2sigma for (56)Fe/(54)Fe and (58)Fe/(54)Fe ratios, respectively (epsilon refers to relative variations in parts per 10 000). For (58)Fe, this precision is an order of magnitude better than what had been achieved before. The method is applied to rocks that could potentially exhibit mass-independent effects, meteorites and Archaean terrestrial samples. The isotopic composition of a 3.8-Ga-old banded iron formation from Isua (IF-G, Greenland), and quartz-pyroxene rocks from Akilia and Innersuartuut (GR91-26 and SM/GR/171770, Greenland) are normal within uncertainties. Similarly, the Orgueil (CI1), Allende (CV3.2), Eagle Station (ESPAL), Brenham (MGPAL), and Old Woman (IIAB) meteorites do not show any mass-independent effect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0497095

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Dauphas, N., Janney, P. E., Mendybaev, R. A., Wadhwa, M., Richter, F. M., Davis, A. M., van Zuilen, M., Hines, R., & Foley, C. N.
Venue
Analytical Chemistry
Published
2004-08-27
Volume
76
Issue
19
Pages
5855-5863
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2055756034
Cited by
187
References
3
FWCI
6.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.