CoChat

Buffer Loading for Counteracting Metal Salt-Induced Signal Suppression in Electrospray Ionization

Open access
Iavarone, Anthony T., Udekwu, Osita A., Williams, Evan R. · 2004 · Analytical Chemistry
Cited by 143

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The decrease in the sensitivity of electrospray ionization mass spectrometry caused by the presence of metal salts, such as sodium chloride, in the sample matrix is well known and is particularly problematic for biological samples. We report here that addition of high levels of ammonium acetate can improve analyte signal in aqueous electrospray solutions and counteracts the signal suppression caused by sodium chloride. A approximately 3-fold improvement in S/N is obtained by adding 8 M ammonium acetate to aqueous solutions of cytochrome c without added sodium chloride. No organic solvents or acids are added into the electrospray solutions. The signal-to-noise ratios of cytochrome c and ubiquitin (10(-)(5) M) ions formed from aqueous solutions containing 2.0 x 10(-)(2) M sodium chloride are improved by factors of approximately 7 and 11, respectively, by adding 7 M ammonium acetate to the solution. We propose that this effect is a result of the precipitation of Na(+) and Cl(-) from solution within the evaporating electrospray droplets prior to the formation of gas-phase protein ions. This method is potentially useful for improving the abundance of protein ions formed from solutions in which the molecules have a nativelike conformation and is particularly advantageous for such solutions that have high levels of sodium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac049724+

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 143

Metadata

Authors
Iavarone, A. T., Udekwu, O. A., & Williams, E. R.
Venue
Analytical Chemistry
Published
2004-05-29
Volume
76
Issue
14
Pages
3944-3950
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2090989207
Cited by
143
References
2
FWCI
1.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Buffer Loading for Counteracting Metal Salt-Induced Signal Suppression in Electrospray Ionization. https://app.cochat.ai/papers/10.1021/ac049724+
The paper
Iavarone, A. T., Udekwu, O. A., & Williams, E. R. (2004). Buffer Loading for Counteracting Metal Salt-Induced Signal Suppression in Electrospray Ionization. Analytical Chemistry. https://doi.org/10.1021/ac049724%2B

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.