The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Label-Free Electrochemical Detection for Aptamer-Based Array Electrodes
Abstract
An electrochemical impedance spectroscopy method of detection for aptamer-based array electrodes is reported in which the binding of aptamers immobilized on gold electrodes leads to impedance changes associated with target protein binding events. Human IgE was used as a model target protein and incubated with the aptamer-based array consisting of single-stranded DNA containing a hairpin loop. To increase the binding efficiency for proteins, a hybrid modified layer containing aptamers and cysteamine was fabricated on the photolithographic gold surface through molecular self-assembly. Atomic force microscopy analysis demonstrated that human IgE could be specifically captured by the aptamer and stand well above the self-assembled monolayer (SAM) surface. Compared to immunosensing methods using anti-human IgE antibody as the recognition element, impedance spectroscopy detection could provide higher sensitivity and better selectivity for aptamer-modified electrodes. The results of this method show good correlation for human IgE in the range of 2.5-100 nM. A detection limit of 0.1 nM (5 fmol in a 50-microL sample) was obtained, and an average of the relative standard deviation was <10%. The method herein describes the first label-free detection for arrayed electrodes utilizing electrochemical impedance spectroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Aptamer-Functionalized Au Nanoparticles for the Amplified Optical Detection of Thrombin
Pavlov, V., Xiao, Y., Shlyahovsky, B., & Willner, I. (2004) · Journal of the American Chemical Society · doi:10.1021/ja046970u · Cited by 692
Nucleic Acid AptamersFrom Selection in Vitro to Applications in Vivo
Famulok, M., Mayer, G., & Blind, M. (2000) · Accounts of Chemical Research · doi:10.1021/ar960167q · Cited by 422
High-affinity oligonucleotide ligands to human IgE inhibit binding to Fc ε receptor I
Wiegand, T. W., Williams, P. B., Dreskin, S. C., Jouvin, M. H., Kinet, J. P., & Tasset, D. (1996) · The Journal of Immunology · doi:10.4049/jimmunol.157.1.221 · Cited by 351
Micromechanical Detection of Proteins Using Aptamer-Based Receptor Molecules
Savran, C. A., Knudsen, S. M., Ellington, A. D., & Manalis, S. R. (2004) · Analytical Chemistry · doi:10.1021/ac049859f · Cited by 310
Yang, L., Li, Y., Griffis, C. L., & Johnson, M. G. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.10.009 · Cited by 302
Aptamer-based biosensor arrays for detection and quantification of biological macromolecules
McCauley, T. G., Hamaguchi, N., & Stanton, M. (2003) · Analytical Biochemistry · doi:10.1016/s0003-2697(03)00297-5 · Cited by 266
Patolsky, F., Zayats, M., Katz, E., & Willner, I. (1999) · Analytical Chemistry · doi:10.1021/ac9901541 · Cited by 234
Automated selection of aptamers against protein targets translated in vitro: from gene to aptamer
Cox, J. C. (2002) · Nucleic Acids Research · doi:10.1093/nar/gnf107 · Cited by 173
Potential applications of DNA microarrays in biodefense-related diagnostics
Stenger, D. A., Andreadis, J. D., Voraa, G. J., & Pancrazio, J. J. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00321-x · Cited by 31
Multiplexed, Targeted Gene Expression Profiling and Genetic Analysis on Electronic Microarrays
Weidenhammer, E. M., Kahl, B. F., Wang, L., Wang, L. W., Duhon, M., Jackson, J. A., Slater, M., & Xu, X. S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.11.1873 · Cited by 31
Cited by
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Reducing Sugar: New Functional Molecules for the Green Synthesis of Graphene Nanosheets
Zhu, C., Guo, S., Fang, Y., & Dong, S. (2010) · ACS Nano · doi:10.1021/nn1002387 · Cited by 1,442
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
The use of electrochemical impedance spectroscopy for biosensing
Lisdat, F., & Schäfer, D. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1970-7 · Cited by 858
Aptamers and Their Biological Applications
Song, K.-M., Lee, S., & Ban, C. (2012) · Sensors · doi:10.3390/s120100612 · Cited by 821
Metadata
- Authors
- Xu, D., Xu, D., Yu, X., Liu, Z., He, W., & Ma, Z.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-07-08
- Volume
- 77
- Issue
- 16
- Pages
- 5107-5113
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2048496140
- Cited by
- 304
- References
- 11
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.