The DOI matches its Crossref record.
Application of Fast Fourier Transform Cross-Correlation for the Alignment of Large Chromatographic and Spectral Datasets
Open accessAbstract
Preprocessing of chromatographic and spectral data is an important aspect of analytical sciences. In particular, recent advances in proteomics have resulted in the generation of large data sets that require analysis. To assist accurate comparison of chemical signals, we propose two methods for the alignment of multiple spectral data sets. Based on methods previously described, each chromatograph or spectrum to be aligned is divided and aligned as individual segments to a reference. However, our methods make use of fast Fourier transform for the rapid computation of a cross-correlation function that enables alignments between samples to be optimized. The proposed methods are demonstrated in comparison with an existing method on a chromatographic and a mass spectral data set. It is shown that our methods provide an advantage of speed and a reduction of the number of input parameters required. The software implementations for the proposed alignment methods are available under the downloads section at http://ptcl.chem.ox.ac.uk/~jwong/specalign.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
icoshift: A versatile tool for the rapid alignment of 1D NMR spectra
Savorani, F., Tomasi, G., & Engelsen, S. B. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.11.012 · Cited by 850
Data processing for mass spectrometry-based metabolomics
Katajamaa, M., & Orešič, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.021 · Cited by 616
Chemometric methods in data processing of mass spectrometry-based metabolomics: A review
Yi, L., Dong, N., Yun, Y., Deng, B., Ren, D., Liu, S., & Liang, Y. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.02.001 · Cited by 305
Biomarker discovery in mass spectral profiles by means of selectivity ratio plot
Rajalahti, T., Arneberg, R., Berven, F. S., Myhr, K.-M., Ulvik, R. J., & Kvalheim, O. M. (2009) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2008.08.004 · Cited by 277
Automated alignment of chromatographic data
Skov, T., van den Berg, F., Tomasi, G., & Bro, R. (2006) · Journal of Chemometrics · doi:10.1002/cem.1031 · Cited by 274
Metadata
- Authors
- Wong, J. W. H., Durante, C., & Cartwright, H. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-08-04
- Volume
- 77
- Issue
- 17
- Pages
- 5655-5661
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2011897000
- Cited by
- 171
- References
- 0
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Fast Fourier Transform Cross-Correlation for the Alignment of Large Chromatographic and Spectral Datasets. https://app.cochat.ai/papers/10.1021/ac050619p
- The paper
- Wong, J. W. H., Durante, C., & Cartwright, H. M. (2005). Application of Fast Fourier Transform Cross-Correlation for the Alignment of Large Chromatographic and Spectral Datasets. Analytical Chemistry. https://doi.org/10.1021/ac050619p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.