Measuring Fifteen Endogenous Estrogens Simultaneously in Human Urine by High-Performance Liquid Chromatography-Mass Spectrometry
Abstract
A sensitive, specific, accurate, and precise high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry method for measuring the absolute quantities of 15 endogenous estrogens and their metabolites in human urine has been developed and validated. The method requires a single hydrolysis/extraction/derivatization step and only 0.5 mL of urine, yet is capable of simultaneously quantifying estrone and its 2-, 4-methoxy and 2-, 4-, and 16alpha-hydroxy derivatives, and 2-hydroxyestrone-3-methyl ether; estradiol and its 2-, 4-methoxy and 2-, 16alpha-hydroxy derivatives, 16-epiestriol, 17-epiestriol, and 16-ketoestradiol in pre- and postmenopausal women as well as men. Standard curves are linear over a 10(3)-fold concentration range with the standard error of the estimate (SEE) and the relative standard error of the estimate (RSEE) for the linear regression line ranging from 0.0131 to 0.1760 and 1.2 to 7.3%, respectively. The lower limit of quantitation for each estrogen is 0.02 ng/0.5 mL urine sample (2 pg on column), with the percent recovery of a known added amount of compound (accuracy) of 96-107% and an overall precision, including the hydrolysis, extraction, and derivatization steps, of 1-5% relative standard deviation (RSD) for samples prepared concurrently and 1-12% RSD for samples prepared in separate batches. Since individual patterns of estrogen metabolism may influence the risk of breast cancer, accurate, precise, and specific measurement of endogenous estrogen metabolites in biological matrixes will facilitate future research on breast cancer prevention, screening, and treatment.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Chemical labelling has become a widely employed approach not only in NPs research, but also in proteomics, food-safety, forensics, and environmental analysis.
“Chemical labelling has become a widely employed approach not only in the NPs research, but also in other research fields including proteomics,98,99 food-safety,100,101 forensics,102,103 environmental analysis.104,105”
From Connecting metabolome and phenotype: recent advances in functional metabolomics tools for the identification of bioactive natural products (2024) · cites this paper as [103]
The citation lists haven’t been fetched yet
References 18 · Cited by 227
- Authors
- Xu, X., Veenstra, T. D., Fox, S. D., Roman, J. M., Issaq, H. J., Falk, R., Saavedra, J. E., Keefer, L. K., & Ziegler, R. G.
- Affiliations
- Frederick National Laboratory for Cancer Research (US)
- Corresponding author
- Veenstra, Timothy D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-09-09
- Volume
- 77
- Issue
- 20
- Pages
- 6646-6654
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2088904058
- Cited by
- 227
- References
- 18
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 5 · 2023: 3 · 2022: 7 · 2021: 6 · 2020: 10 · 2019: 7 · 2018: 6 · 2017: 7 · 2016: 11 · 2015: 13 · 2014: 12 · 2013: 14 · 2012: 22
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- DigitalCommons-Cedarville (Cedarville University) (submittedVersion)
- Funders
- U.S. Department of Health and Human Services
- National Institutes of Health (n01co12400-79-0-22)
- National Cancer Institute (N01CO12400)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Estrogen and related hormone effects
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Effects and risks of endocrine disrupting chemicals
- Keywords
- endogenous estrogen, estrogen metabolites, human urine, estrone, estradiol, simultaneous determination, breast cancer risk, men, method validation
- MeSH terms
- Adult, Aged, Chromatography, High Pressure Liquid, Estrogens, Female, Humans, Male, Middle Aged, Molecular Weight, Quality Control, Reference Values, Sensitivity and Specificity, Mass Spectrometry, Time Factors, Molecular Structure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review