Measuring Fifteen Endogenous Estrogens Simultaneously in Human Urine by High-Performance Liquid Chromatography-Mass Spectrometry

Xu, Xia, Veenstra, Timothy D., Fox, Stephen D., Roman, John M., Issaq, Haleem J., Falk, Roni, Saavedra, Joseph E., Keefer, Larry K. +1 more·2005·Analytical Chemistry

Abstract

A sensitive, specific, accurate, and precise high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry method for measuring the absolute quantities of 15 endogenous estrogens and their metabolites in human urine has been developed and validated. The method requires a single hydrolysis/extraction/derivatization step and only 0.5 mL of urine, yet is capable of simultaneously quantifying estrone and its 2-, 4-methoxy and 2-, 4-, and 16alpha-hydroxy derivatives, and 2-hydroxyestrone-3-methyl ether; estradiol and its 2-, 4-methoxy and 2-, 16alpha-hydroxy derivatives, 16-epiestriol, 17-epiestriol, and 16-ketoestradiol in pre- and postmenopausal women as well as men. Standard curves are linear over a 10(3)-fold concentration range with the standard error of the estimate (SEE) and the relative standard error of the estimate (RSEE) for the linear regression line ranging from 0.0131 to 0.1760 and 1.2 to 7.3%, respectively. The lower limit of quantitation for each estrogen is 0.02 ng/0.5 mL urine sample (2 pg on column), with the percent recovery of a known added amount of compound (accuracy) of 96-107% and an overall precision, including the hydrolysis, extraction, and derivatization steps, of 1-5% relative standard deviation (RSD) for samples prepared concurrently and 1-12% RSD for samples prepared in separate batches. Since individual patterns of estrogen metabolism may influence the risk of breast cancer, accurate, precise, and specific measurement of endogenous estrogen metabolites in biological matrixes will facilitate future research on breast cancer prevention, screening, and treatment.

Integrity signals

Registry

Crossref · 10.1021/ac050697c

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 18 · Cited by 227

Authors
Xu, X., Veenstra, T. D., Fox, S. D., Roman, J. M., Issaq, H. J., Falk, R., Saavedra, J. E., Keefer, L. K., & Ziegler, R. G.
Affiliations
Frederick National Laboratory for Cancer Research (US)
Corresponding author
Veenstra, Timothy D.
Venue
Analytical Chemistry
Published
2005-09-09
Volume
77
Issue
20
Pages
6646-6654
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2088904058
Cited by
227
References
18
Citations by year
2026: 3 · 2025: 6 · 2024: 5 · 2023: 3 · 2022: 7 · 2021: 6 · 2020: 10 · 2019: 7 · 2018: 6 · 2017: 7 · 2016: 11 · 2015: 13 · 2014: 12 · 2013: 14 · 2012: 22
FWCI
6.61
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • DigitalCommons-Cedarville (Cedarville University) (submittedVersion)
Funders
  • U.S. Department of Health and Human Services
  • National Institutes of Health (n01co12400-79-0-22)
  • National Cancer Institute (N01CO12400)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Estrogen and related hormone effects
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Effects and risks of endocrine disrupting chemicals
Keywords
endogenous estrogen, estrogen metabolites, human urine, estrone, estradiol, simultaneous determination, breast cancer risk, men, method validation
MeSH terms
Adult, Aged, Chromatography, High Pressure Liquid, Estrogens, Female, Humans, Male, Middle Aged, Molecular Weight, Quality Control, Reference Values, Sensitivity and Specificity, Mass Spectrometry, Time Factors, Molecular Structure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review