CoChat

Measurement of the Isotope Enrichment of Stable Isotope-Labeled Proteins Using High-Resolution Mass Spectra of Peptides

MacCoss, Michael J., Wu, Christine C., Matthews, Dwight E., Yates, John R. · 2005 · Analytical Chemistry
Cited by 113

The DOI matches its Crossref record.

Abstract

Stable isotope-enriched molecules are used as internal standards and as tracers of in vivo substrate metabolism. The accurate conversion of measured ratios in the mass spectrometer to mole ratios is complicated because a polyatomic molecule containing enriched atoms will result in a combinatorial distribution of isotopomers depending on the enrichment and number of "labeled" atoms. This effect could potentially cause a large error in the mole ratio measurement depending on which isotope peak or peaks were used to determine the ratio. We report a computational method that predicts isotope distributions over a range of enrichments and compares the predicted distributions to experimental peptide isotope distributions obtained by Fourier transform ion cyclotron resonance mass spectrometry. Our approach is accurate with measured enrichments within 1.5% of expected isotope distributions. The method is also precise with 4.9, 2.0, and 0.8% relative standard deviations for peptides containing 59, 79, and 99 atom % excess (15)N, respectively. The approach is automated making isotope enrichment calculations possible for thousands of peptides in a single muLC-FTICR-MS experiment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0508393

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
MacCoss, M. J., Wu, C. C., Matthews, D. E., & Yates, J. R.
Venue
Analytical Chemistry
Published
2005-10-22
Volume
77
Issue
23
Pages
7646-7653
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1972358546
Cited by
113
References
0
FWCI
5.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.