The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Bio-Bar-Code Assay Based upon Dithiothreitol-Induced Oligonucleotide Release
Abstract
The recently developed bio-bar-code assay for the PCR-less detection of protein and nucleic acid targets has been shown to be extraordinarily sensitive, exhibiting low attomolar sensitivity for protein targets and high zeptomolar sensitivity for nucleic acid targets. In the case of DNA detection, the original assay relies on three distinct oligonucleotide strands on a single nanoparticle for target identification and signal amplification. Herein, we report the development of a new nanoparticle probe that can be used in the bio-bar-code assay, which requires only one thiolated oligonucleotide strand. This new assay relies on the ability to liberate the adsorbed thiolated oligonucleotides from the gold nanoparticle surface with dithiothreitol (DTT), which simplifies the assay and increases its quantitative capabilities. The utility of this new DTT-based system is demonstrated by detecting a mock mRNA target using both fluorescent and scanometric assay readouts. When the scanometric readout is used, the sensitivity of the assay is 7 aM and quantification can be accomplished over the low-attomolar to the mid-femtomolar concentration range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluidity of Bound Hydration Layers
Raviv, U., & Klein, J. (2002) · Science · doi:10.1126/science.1074481 · Cited by 721
Cited by
Gold nanoparticles: preparation, properties, and applications in bionanotechnology
Yeh, Y.-C., Creran, B., & Rotello, V. M. (2012) · Nanoscale · doi:10.1039/c1nr11188d · Cited by 1,346
Lee, J., Han, M. S., & Mirkin, C. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700269 · Cited by 1,308
Self-citationMaximizing DNA Loading on a Range of Gold Nanoparticle Sizes
Hurst, S. J., Lytton-Jean, A. K. R., & Mirkin, C. A. (2006) · Analytical Chemistry · doi:10.1021/ac0613582 · Cited by 1,214
Self-citationMultiplexed Detection of Protein Cancer Markers with Biobarcoded Nanoparticle Probes
Stoeva, S. I., Lee, J.-S., Smith, J. E., Rosen, S. T., & Mirkin, C. A. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0613106 · Cited by 419
Self-citationFree-standing nanoparticle superlattice sheets controlled by DNA
Cheng, W., Campolongo, M. J., Cha, J. J., Tan, S. J., Umbach, C. C., Muller, D. A., & Luo, D. (2009) · Nature Materials · doi:10.1038/nmat2440 · Cited by 398
Gold nanoparticle-based signal amplification for biosensing
Cao, X., Ye, Y., & Liu, S. (2011) · Analytical Biochemistry · doi:10.1016/j.ab.2011.05.027 · Cited by 393
Ye, B., & Yin, B. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803069 · Cited by 386
Electrical nanogap devices for biosensing
Chen, X., Guo, Z., Yang, G.-M., Li, J., Li, M.-Q., Liu, J.-H., & Huang, X.-J. (2010) · Materials Today · doi:10.1016/s1369-7021(10)70201-7 · Cited by 326
Hu, K., Lan, D., Li, X., & Zhang, S. (2008) · Analytical Chemistry · doi:10.1021/ac8017197 · Cited by 324
Electrochemical DNAzyme Sensor for Lead Based on Amplification of DNA−Au Bio-Bar Codes
Shen, L., Chen, Z., Li, Y., He, S., Xie, S., Xu, X., Liang, Z., Meng, X., Li, Q., Zhu, Z., et al. (2008) · Analytical Chemistry · doi:10.1021/ac800601y · Cited by 278
Lee, J., Han, M. S., & Mirkin, C. A. (2007) · Angewandte Chemie · doi:10.1002/ange.200700269 · Cited by 265
Self-citation
Metadata
- Authors
- Thaxton, C. S., Hill, H. D., Georganopoulou, D. G., Stoeva, S. I., & Mirkin, C. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-11-10
- Volume
- 77
- Issue
- 24
- Pages
- 8174-8178
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2049947606
- Cited by
- 175
- References
- 1
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.