The DOI matches its Crossref record.
Performance of a Linear Ion Trap-Orbitrap Hybrid for Peptide Analysis
Abstract
Proteomic analysis of digested complex protein mixtures has become a useful strategy to identify proteins involved in biological processes. We have evaluated the use of a new mass spectrometer that combines a linear ion trap and an Orbitrap to create a hybrid tandem mass spectrometer. A digested submandibular/sublingual saliva sample was used for the analysis. We find the instrument is capable of mass resolution in excess of 40,000 and mass measurement accuracies of less than 2 ppm for the analysis of complex peptide mixtures. Such high mass accuracy allowed the elimination of virtually any false positive peptide identifications, suggesting that peptides that do not match the specificity of the protease used in the digestion of the sample should not automatically be considered as false positives. Tandem mass spectra from the linear ion trap and from the Orbitrap have very similar ion abundance ratios. We conclude this instrument will be well suited for shotgun proteomic types of analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Self-citationProteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Self-citationMass spectrometry for proteomics
Han, X., Aslanian, A., & Yates, J. R. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.07.024 · Cited by 734
Self-citationHuman body fluid proteome analysis
Hu, S., Loo, J. A., & Wong, D. T. (2006) · PROTEOMICS · doi:10.1002/pmic.200600284 · Cited by 533
ProLuCID: An improved SEQUEST-like algorithm with enhanced sensitivity and specificity
Xu, T., Park, S. K., Venable, J. D., Wohlschlegel, J. A., Diedrich, J. K., Cociorva, D., Lu, B., Liao, L., Hewel, J., Han, X., et al. (2015) · Journal of Proteomics · doi:10.1016/j.jprot.2015.07.001 · Cited by 511
Self-citationOrbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
Denny, P., Hagen, F. K., Hardt, M., Liao, L., Yan, W., Arellanno, M., Bassilian, S., Bedi, G. S., Boontheung, P., Cociorva, D., et al. (2008) · Journal of Proteome Research · doi:10.1021/pr700764j · Cited by 445
Self-citationA quantitative analysis software tool for mass spectrometry–based proteomics
Park, S. K., Venable, J. D., Xu, T., & Yates, J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1195 · Cited by 401
Self-citationSaliva: diagnostics and therapeutic perspectives
Spielmann, N., & Wong, D. (2011) · Oral Diseases · doi:10.1111/j.1601-0825.2010.01773.x · Cited by 378
Orbitrap Mass Analyzer – Overview and Applications in Proteomics
Scigelova, M., & Makarov, A. (2006) · PROTEOMICS · doi:10.1002/pmic.200600528 · Cited by 288
Optimization and Use of Peptide Mass Measurement Accuracy in Shotgun Proteomics
Haas, W., Faherty, B. K., Gerber, S. A., Elias, J. E., Beausoleil, S. A., Bakalarski, C. E., Li, X., Villén, J., & Gygi, S. P. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500339-mcp200 · Cited by 261
Metadata
- Authors
- Yates, J. R., Cociorva, D., Liao, L., & Zabrouskov, V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-12-01
- Volume
- 78
- Issue
- 2
- Pages
- 493-500
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2077037916
- Cited by
- 175
- References
- 0
- FWCI
- 9.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.