The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Detection of Human Immunodeficiency Virus Type 1 DNA Sequence Using Plasmonics Nanoprobes
Abstract
This paper describes the use of plasmonics-based nanoprobes that act as molecular sentinels for DNA diagnostics. The plasmonics nanoprobe comprises a metal nanoparticle and a stem-loop DNA molecule tagged with a Raman label. The nanoprobe utilizes the specificity and selectivity of the DNA hairpin probe sequence to detect a specific target DNA sequence of interest. In the absence of target DNA, the stem-loop configuration maintains the Raman label in proximity to the metal nanoparticle, inducing an intense surface-enhanced Raman scattering (SERS) effect that produces a strong Raman signal upon laser excitation. Upon hybridization of a complementary target DNA sequence to the nanoprobe, the stem-loop configuration is disrupted, causing the Raman label to physically separate from the metal nanoparticle, thus quenching the SERS signal. The usefulness and potential application of the plasmonics nanoprobe for diagnosis is demonstrated using the gag gene sequence of the human immunodeficiency virus type 1 (HIV-1). We successfully demonstrated the specificity and selectivity of the plasmonics nanoprobes to detect PCR amplicons of the HIV gene. The potential for combining the spectral selectivity and high sensitivity of the SERS process with inherent molecular specificity of DNA hairpins to diagnose molecular target sequences in homogeneous solutions is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface raman spectroelectrochemistry
Jeanmaire, D. L., & Van Duyne, R. P. (1977) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(77)80224-6 · Cited by 4,738
Fluidity of Bound Hydration Layers
Raviv, U., & Klein, J. (2002) · Science · doi:10.1126/science.1074481 · Cited by 721
Vo-Dinh, T. (1998) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00069-7 · Cited by 498
Self-citation
Cited by
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Noble Metal Nanoparticles for Biosensing Applications
Doria, G., Conde, J., Veigas, B., Giestas, L., Almeida, C., Assunção, M., Rosa, J., & Baptista, P. V. (2012) · Sensors · doi:10.3390/s120201657 · Cited by 708
The plasmon band in noble metal nanoparticles: an introduction to theory and applications
Moores, A., & Goettmann, F. (2006) · New Journal of Chemistry · doi:10.1039/b604038c · Cited by 665
Localized Surface Plasmon Resonance Biosensing: Current Challenges and Approaches
Unser, S., Bruzas, I., He, J., & Sagle, L. (2015) · Sensors · doi:10.3390/s150715684 · Cited by 565
SERS: a versatile tool in chemical and biochemical diagnostics
Hering, K., Cialla, D., Ackermann, K., Dörfer, T., Möller, R., Schneidewind, H., Mattheis, R., Fritzsche, W., Rösch, P., & Popp, J. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1667-3 · Cited by 489
Metadata
- Authors
- Wabuyele, M. B., & Vo-Dinh, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-10-12
- Volume
- 77
- Issue
- 23
- Pages
- 7810-7815
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2085864023
- Cited by
- 236
- References
- 3
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.