The DOI matches its Crossref record.
Magnetic and Gold-Coated Magnetic Nanoparticles as a DNA Sensor
Abstract
In this study, we report the chemical synthesis and functionalization of magnetic and gold-coated magnetic nanoparticles and the immobilization of single-stranded biotinylated oligonucleotides onto these particles. Selected sequences specific to the BRCA1 gene were used as a test platform. The binding of oligonucleotides to these particles was achieved through a streptavidin-biotin bridge via a carbodiimide activation protocol. Particle size and oligonucleotide attachment were confirmed by transmission electron microscopy; oligonucleotide binding was characterized by Fourier transform infrared spectroscopy and hybridization confirmed by fluorescence emission from the fluorophore attached to the target oligonucleotide strand. The rate of hybridization was measured using a spectrofluorometer and a microarray scanner. The rate of hybridization of oligonucleotides bound to the synthesized particles depends on the inorganic support material and its surface chemistry. The rate of hybridization increased concomitantly with the concentration of the probe and the target in the reaction medium. Furthermore, exposure of probe and target oligonucleotide to a combination of target and noncomplementary DNA strand reduced the rate of hybridization, possibly because of steric crowding in the reaction medium and cross-linking between reacting oligonucleotides and the noncomplementary strands. The study undertaken opens several possibilities in bioconjugate attachment to functionalized iron and iron nanocomposite structures for controlled manipulation and handling using magnetic fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Magnetic Nanoparticles: From Design and Synthesis to Real World Applications
Kudr, J., Haddad, Y., Richtera, L., Heger, Z., Cernak, M., Adam, V., & Zitka, O. (2017) · Nanomaterials · doi:10.3390/nano7090243 · Cited by 628
Magnetic solids in analytical chemistry: A review
Aguilar-Arteaga, K., Rodriguez, J. A., & Barrado, E. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.06.043 · Cited by 414
Nanoscale Drug Delivery Systems: From Medicine to Agriculture
Vega-Vásquez, P., Mosier, N. S., & Irudayaraj, J. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00079 · Cited by 323
Self-citationSalgueiriño‐Maceira, V., & Correa‐Duarte, M. A. (2007) · Advanced Materials · doi:10.1002/adma.200700418 · Cited by 284
Metadata
- Authors
- Kouassi, G. K., & Irudayaraj, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-04-20
- Volume
- 78
- Issue
- 10
- Pages
- 3234-3241
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2078954120
- Cited by
- 187
- References
- 0
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic and Gold-Coated Magnetic Nanoparticles as a DNA Sensor. https://app.cochat.ai/papers/10.1021/ac051621j
- The paper
- Kouassi, G. K., & Irudayaraj, J. (2006). Magnetic and Gold-Coated Magnetic Nanoparticles as a DNA Sensor. Analytical Chemistry. https://doi.org/10.1021/ac051621j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.