Peak Capacity Optimization of Peptide Separations in Reversed-Phase Gradient Elution Chromatography: Fixed Column Format
Open accessThe DOI matches its Crossref record.
Abstract
The optimization of peak capacity in gradient elution RPLC is essential for the separation of multicomponent samples such as those encountered in proteomic research. In this work, we study the effect of gradient time (tG), flow rate (F), temperature (T), and final eluent strength (phi(final)) on the peak capacity of separations of peptides that are representative of the range in peptides found in a tryptic digest. We find that there are very strong interactions between the individual variables (e.g., flow rate and gradient time) which make the optimization quite complicated. On a given column, one should first set the gradient time to the longest tolerable and then set the temperature to the highest achievable with the instrument. Next, the flow rate should be optimized using a reasonable but arbitrary value of phi(final). Last, the final eluent strength should be adjusted so that the last solute elutes as close as possible to the gradient time. We also develop an easily implemented, highly efficient, and effective Monte Carlo search strategy to simultaneously optimize all the variables. We find that gradient steepness is an important parameter that influences peak capacity and an optimum range of gradient steepness exists in which the peak capacity is maximized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“Significant effort goes into increasing peak capacity (83), sensitivity (84, 85), reproducibility, and analysis speed of reverse phase chromatography (86, 87).”
BackgroundFast, comprehensive two-dimensional liquid chromatography
Stoll, D. R., Li, X., Wang, X., Carr, P. W., Porter, S. E. G., & Rutan, S. C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.054 · Cited by 396
Self-citationPerez de Souza, L., Alseekh, S., Scossa, F., & Fernie, A. R. (2021) · Nature Methods · doi:10.1038/s41592-021-01116-4 · Cited by 358
Label-free quantification in ion mobility–enhanced data-independent acquisition proteomics
Distler, U., Kuharev, J., Navarro, P., & Tenzer, S. (2016) · Nature Protocols · doi:10.1038/nprot.2016.042 · Cited by 329
Shell particles, trials, tribulations and triumphs
Guiochon, G., & Gritti, F. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.01.080 · Cited by 314
Metadata
- Authors
- Wang, X., Stoll, D. R., Schellinger, A. P., & Carr, P. W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-04-13
- Volume
- 78
- Issue
- 10
- Pages
- 3406-3416
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2058932040
- Cited by
- 141
- References
- 0
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Peak Capacity Optimization of Peptide Separations in Reversed-Phase Gradient Elution Chromatography: Fixed Column Format. https://app.cochat.ai/papers/10.1021/ac0600149
- The paper
- Wang, X., Stoll, D. R., Schellinger, A. P., & Carr, P. W. (2006). Peak Capacity Optimization of Peptide Separations in Reversed-Phase Gradient Elution Chromatography: Fixed Column Format. Analytical Chemistry. https://doi.org/10.1021/ac0600149
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.