Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 329

The DOI matches its Crossref record.

Improving the Instrumental Resolution of Sensors Based on Localized Surface Plasmon Resonance

Dahlin, Andreas B., Tegenfeldt, Jonas O., Höök, Fredrik·2006·Analytical Chemistry

Abstract

The colorimetric variations induced upon changes in interfacial refractive index of nanoscale noble metal structures exhibiting localized surface plasmon resonance (LSPR) provides a convenient means of label-free, affinity-based detection of biomolecular recognition reactions. However, despite being similar in nature to conventional SPR, LSPR has so far suffered from significantly lower data quality in terms of its signal-to-noise ratio (S/N) in typical biomolecular recognition analysis. In this work, generic data analysis algorithms and a simple experimental setup that provide a S/N upon protein binding that is comparable to that of state-of-the art SPR systems are presented. Specifically, it is demonstrated how temporal variations (rate approximately 0.5 Hz) in parameters proportional to the resonance peak position can be recorded simultaneously, yielding a peak position precision of <5 x 10(-4) nm and an extinction noise level of <5 x 10(-6) absorbance units (Abs). This, in turn, is shown to provide a S/N of approximately 2000 (equivalent to a detection limit of <0.1 ng/cm(2)) for typical protein binding reactions. Furthermore, the importance of utilizing changes in both peak position and magnitude is highlighted by comparing different LSPR active noble metal architectures that respond differently to bulk and interfacial refractive index changes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0601967

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 329

Metadata

Authors
Dahlin, A. B., Tegenfeldt, J. O., & Höök, F.
Venue
Analytical Chemistry
Published
2006-05-06
Volume
78
Issue
13
Pages
4416-4423
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2149419211
Cited by
329
References
0
FWCI
11.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improving the Instrumental Resolution of Sensors Based on Localized Surface Plasmon Resonance. https://app.cochat.ai/papers/10.1021/ac0601967
The paper
Dahlin, A. B., Tegenfeldt, J. O., & Höök, F. (2006). Improving the Instrumental Resolution of Sensors Based on Localized Surface Plasmon Resonance. Analytical Chemistry. https://doi.org/10.1021/ac0601967

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.