The DOI matches its Crossref record.
Voltammetric Detection of Mercury and Copper in Seawater Using a Gold Microwire Electrode
Abstract
A procedure is presented by which mercury and copper are determined simultaneously in seawater and dilute acid (0.01 M HCl) by anodic stripping voltammetry using gold microwire electrodes. It was found that anion (halide) adsorption is the cause for a gradual decrease in the height and potential of the mercury peak. The effect is eliminated by including an anion desorption step in the analysis at -0.8 V prior to each scan. This step was found to greatly improve the stability of the scans and enabled the use of background subtraction. Advantages of the microwire electrodes were a low roughness of the surface, without a need for pretreatment, and a very small diffusion layer (2 microm with stirring). Under the optimized voltammetric conditions, the detection limits were 6 pM mercury and 25 pM copper using 300-s deposition. These values are well below those reported previously for other electrodes including rotating disk electrodes. Measurements of the influence of the major anions I-, Br-, Cl-, SO4(2-), F-, HCO3-, and B(OH)4 on the response for mercury showed that bromide and chloride are predominantly responsible for the underpotential deposition mechanism of mercury in seawater. The method was applied to coastal water samples from Liverpool Bay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kumar Jena, B., & Retna Raj, C. (2008) · Analytical Chemistry · doi:10.1021/ac071064w · Cited by 352
A Highly Selective DNAzyme Sensor for Mercuric Ions
Hollenstein, M., Hipolito, C., Lam, C., Dietrich, D., & Perrin, D. M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800960 · Cited by 317
Li, Z., Xia, S., Wang, J., Bian, C., & Tong, J. (2016) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.08.061 · Cited by 63
Metadata
- Authors
- Salaün, P., & van den Berg, C. M. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-05-27
- Volume
- 78
- Issue
- 14
- Pages
- 5052-5060
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2044423296
- Cited by
- 163
- References
- 0
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Voltammetric Detection of Mercury and Copper in Seawater Using a Gold Microwire Electrode. https://app.cochat.ai/papers/10.1021/ac060231+
- The paper
- Salaün, P., & van den Berg, C. M. G. (2006). Voltammetric Detection of Mercury and Copper in Seawater Using a Gold Microwire Electrode. Analytical Chemistry. https://doi.org/10.1021/ac060231%2B
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.