The DOI matches its Crossref record.
High-Throughput and High-Resolution Flow Cytometry in Molded Microfluidic Devices
Abstract
We describe the design, fabrication, and operation of two types of flow cytometers based on microfluidic devices made of a single cast of poly(dimethylsiloxane). The stream of particles or cells injected into the devices is hydrodynamically focused in both transverse and lateral directions, has a uniform velocity, and has adjustable diameter and shape. The cytometry system built around the first microfluidic device has fluorescence detection accuracy comparable with that of a commercial flow cytometer and can analyze as many as 17 000 particles/s. This high-throughput microfluidic device could be used in inexpensive stand-alone cytometers or as a part of integrated microanalysis systems. In the second device, a stream of particles is focused to a flow layer of a submicrometer thickness that allows imaging the particles with a high numerical aperture microscope objective. To take long-exposure, low-light fluorescence images of live cells, the device is placed on a moving stage, which accurately balances the translational motion of particles in the flow. The achieved resolution is comparable to that of still micrographs. This high-resolution device could be used for analysis of morphology and fluorescence distribution in cells in continuous flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Focusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW)
Shi, J., Mao, X., Ahmed, D., Colletti, A., & Huang, T. J. (2008) · Lab Chip · doi:10.1039/b716321e · Cited by 439
Micro Total Analysis Systems: Latest Achievements
West, J., Becker, M., Tombrink, S., & Manz, A. (2008) · Analytical Chemistry · doi:10.1021/ac800680j · Cited by 423
Sheathless inertial cell ordering for extreme throughput flow cytometry
Hur, S. C., Tse, H. T. K., & Di Carlo, D. (2010) · Lab Chip · doi:10.1039/b919495a · Cited by 368
Metadata
- Authors
- Simonnet, C., & Groisman, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-07-13
- Volume
- 78
- Issue
- 16
- Pages
- 5653-5663
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2052419975
- Cited by
- 181
- References
- 0
- FWCI
- 12.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.