Automated Ultra-High-Pressure Multidimensional Protein Identification Technology (UHP-MudPIT) for Improved Peptide Identification of Proteomic Samples
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Multidimensional separation is one of the most successful approaches for proteomics studies that deal with complex samples. We have developed an automated ultra-high-pressure multidimensional liquid chromatography system that operates up to approximately 20 kpsi to improve separations and increase protein coverage from limited amount of samples. The reversed-phase gradient is operated in the constant-flow mode opposed to the constant-pressure mode, which is typical of previous ultra-high-pressure systems. In contrast to constant-pressure systems, the gradient shape is fully controllable and can be optimized for the type of samples to be run. The system also features fast sample loading/desalting using a vented column approach to improve sample throughput. This approach was validated on a soluble fraction from yeast lysate where we achieved approximately 30% more protein identifications using a 60-cm-long triphasic capillary column than with our traditional approach. Advantages of the use of a relatively long reversed-phase column (approximately 50 cm) for MudPIT-type experiments are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Self-citationProteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“HPLC has become a standard front end for many biological applications and gave rise to several LC/MS setups (33, 37, 77).”
BackgroundResultInfluentialSelf-citationQuantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
A Critical Review of Bottom-Up Proteomics: The Good, the Bad, and the Future of This Field
Dupree, E. J., Jayathirtha, M., Yorkey, H., Mihasan, M., Petre, B. A., & Darie, C. C. (2020) · Proteomes · doi:10.3390/proteomes8030014 · Cited by 353
Deep and Highly Sensitive Proteome Coverage by LC-MS/MS Without Prefractionation
Thakur, S. S., Geiger, T., Chatterjee, B., Bandilla, P., Fröhlich, F., Cox, J., & Mann, M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.003699 · Cited by 337
Metadata
- Authors
- Motoyama, A., Venable, J. D., Ruse, C. I., & Yates, J. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-05-26
- Volume
- 78
- Issue
- 14
- Pages
- 5109-5118
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1992445111
- Cited by
- 136
- References
- 1
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.