The DOI matches its Crossref record.
Simultaneous Quantitative Analysis of Metabolites Using Ion-Pair Liquid Chromatography−Electrospray Ionization Mass Spectrometry
Abstract
We have developed an analytical method, consisting of ion-pair liquid chromatography coupled to electrospray ionization mass spectrometry (IP-LC-ESI-MS), for the simultaneous quantitative analysis of several key classes of polar metabolites, like nucleotides, coenzyme A esters, sugar nucleotides, and sugar bisphosphates. The use of the ion-pair agent hexylamine and optimization of the pH of the mobile phases were critical parameters in obtaining good retention and peak shapes of many of the above-mentioned polar and acidic metabolites that are impossible to analyze using standard reversed-phase LC/MS. Optimum conditions were found when using a gradient from 5 mM hexylamine in water (pH 6.3) to 90% methanol/10% 10 mM ammonium acetate (pH 8.5). The IP-LC-ESI-MS method was extensively validated by determining the linearity (R2 > 0.995), sensitivity (limit of detection 0.1-1 ng), repeatability, and reproducibility (relative standard deviation <10%). The IP-LC-ESI-MS method was shown to be a useful tool for microbial metabolomics, i.e., the comprehensive quantitative analysis of metabolites in extracts of microorganisms, and for the determination of the energy charge, i.e., the cellular energy status, as an overall quality measure for the sample workup and analytical protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Absolute metabolite concentrations and implied enzyme active site occupancy in Escherichia coli
Bennett, B. D., Kimball, E. H., Gao, M., Osterhout, R., Van Dien, S. J., & Rabinowitz, J. D. (2009) · Nature Chemical Biology · doi:10.1038/nchembio.186 · Cited by 1,830
Vuckovic, D. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6039-y · Cited by 532
Analytical strategies for LC–MS-based targeted metabolomics
Lu, W., Bennett, B. D., & Rabinowitz, J. D. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.04.031 · Cited by 481
Metabolite Measurement: Pitfalls to Avoid and Practices to Follow
Lu, W., Su, X., Klein, M. S., Lewis, I. A., Fiehn, O., & Rabinowitz, J. D. (2017) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061516-044952 · Cited by 462
Biomarkers of NAFLD progression: a lipidomics approach to an epidemic
Gorden, D. L., Myers, D. S., Ivanova, P. T., Fahy, E., Maurya, M. R., Gupta, S., Min, J., Spann, N. J., McDonald, J. G., Kelly, S. L., et al. (2015) · Journal of Lipid Research · doi:10.1194/jlr.p056002 · Cited by 372
Metadata
- Authors
- Coulier, L., Bas, R., Jespersen, S., Verheij, E., van der Werf, M. J., & Hankemeier, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-07-22
- Volume
- 78
- Issue
- 18
- Pages
- 6573-6582
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2035490018
- Cited by
- 242
- References
- 0
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Quantitative Analysis of Metabolites Using Ion-Pair Liquid Chromatography−Electrospray Ionization Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac0607616
- The paper
- Coulier, L., Bas, R., Jespersen, S., Verheij, E., van der Werf, M. J., & Hankemeier, T. (2006). Simultaneous Quantitative Analysis of Metabolites Using Ion-Pair Liquid Chromatography−Electrospray Ionization Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac0607616
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.