CoChat

Ultratrace LC/MS Proteomic Analysis Using 10-μm-i.d. Porous Layer Open Tubular Poly(styrene−divinylbenzene) Capillary Columns

Yue, Guihua, Luo, Quanzhou, Zhang, Jian, Wu, Shiaw-Lin, Karger, Barry L. · 2007 · Analytical Chemistry
Cited by 156

The DOI matches its Crossref record.

Abstract

In this paper, the preparation and performance of long, high-efficiency poly(styrene-divinylbenzene) (PS-DVB), 10-microm-i.d. porous layer open tubular (PLOT) capillary columns are described. PLOT capillaries ( approximately 3% RSD column-to-column retention time), with relatively high permeability, were prepared by in-situ polymerization. Relatively high loading capacities, approximately 100 fmol for angiotensin I and approximately 50 fmol for insulin, were obtained with a 4.2 m x 10-microm-i.d. PLOT column. Low detection levels (attomole to sub-attomole) were achieved when the column was coupled on-line with a linear ion trap MS (LTQ). Analysis of human epidermal growth factor receptor (EGFR), a large transmembrane tyrosine kinase receptor with heterogeneous phosphorylation and glycosylation structures, was obtained at the 25 fmol level. The PLOT column yielded a peak capacity of approximately 400 for the separation of a complex tryptic digest mixture when the sample preparation included a 50-microm-i.d. PS-DVB monolithic precolumn and ESI-MS detection. As an example of the power of the column, 3046 unique peptides covering 566 distinct Methanosarcina acetivorans proteins were identified from a 50 ng in-gel tryptic digest sample combining five cuts in a single LC/MS/MS analysis using the LTQ. The results demonstrate the potential of the PLOT column for high-resolution LC/MS at the ultratrace level.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac061411m

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 156

Metadata

Authors
Yue, G., Luo, Q., Zhang, J., Wu, S.-L., & Karger, B. L.
Venue
Analytical Chemistry
Published
2006-12-09
Volume
79
Issue
3
Pages
938-946
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2065429223
Cited by
156
References
0
FWCI
4.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultratrace LC/MS Proteomic Analysis Using 10-μm-i.d. Porous Layer Open Tubular Poly(styrene−divinylbenzene) Capillary Columns. https://app.cochat.ai/papers/10.1021/ac061411m
The paper
Yue, G., Luo, Q., Zhang, J., Wu, S.-L., & Karger, B. L. (2007). Ultratrace LC/MS Proteomic Analysis Using 10-μm-i.d. Porous Layer Open Tubular Poly(styrene−divinylbenzene) Capillary Columns. Analytical Chemistry. https://doi.org/10.1021/ac061411m

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.