The DOI matches its Crossref record.
Droplet Dynamics and Ionization Mechanisms in Desorption Electrospray Ionization Mass Spectrometry
Abstract
A droplet pickup and other mechanisms have been suggested for the ionization of biomolecules like peptides and proteins by desorption electrospray ionization. To verify this hypothesis phase Doppler particle analysis was used to study the sizes and velocities of droplets involved in DESI. It was found that impacting droplets typically have velocities of 120 m/s and average diameters of 2-4 microm. Small differences in sprayer construction influence the operating conditions at which droplets of these dimensions are produced. Under these conditions, the kinetic energy per impacting water molecule is less than 0.6 meV and sputtering through momentum transfer during collisions or ionization by other electronic processes is unlikely. Droplets arrive at the surface with velocities well below the speed of sound in common materials, thereby excluding the possibility of ionization by shockwave formation. Some droplets appear to roll along the surface, increasing contact time and presumably the amount of material that is taken up into droplets during conditions typical of the DESI experiment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Organic Reactions in Microdroplets: Reaction Acceleration Revealed by Mass Spectrometry
Yan, X., Bain, R. M., & Cooks, R. G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201602270 · Cited by 583
Self-citationAbiotic production of sugar phosphates and uridine ribonucleoside in aqueous microdroplets
Nam, I., Lee, J. K., Nam, H. G., & Zare, R. N. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1714896114 · Cited by 262
Huang, K.-H., Wei, Z., & Cooks, R. G. (2021) · Chemical Science · doi:10.1039/d0sc05625a · Cited by 176
Self-citationAbiotic synthesis of purine and pyrimidine ribonucleosides in aqueous microdroplets
Nam, I., Nam, H. G., & Zare, R. N. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1718559115 · Cited by 157
Applications of Mass Spectrometry for Clinical Diagnostics: The Influence of Turnaround Time
Swiner, D. J., Jackson, S., Burris, B. J., & Badu-Tawiah, A. K. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04901 · Cited by 73
Metadata
- Authors
- Venter, A., Sojka, P. E., & Cooks, R. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-11-15
- Volume
- 78
- Issue
- 24
- Pages
- 8549-8555
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2018197304
- Cited by
- 361
- References
- 0
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Droplet Dynamics and Ionization Mechanisms in Desorption Electrospray Ionization Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac0615807
- The paper
- Venter, A., Sojka, P. E., & Cooks, R. G. (2006). Droplet Dynamics and Ionization Mechanisms in Desorption Electrospray Ionization Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac0615807
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.