The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Self-Assembled Colloidal Arrays as Three-Dimensional Nanofluidic Sieves for Separation of Biomolecules on Microchips
Abstract
We report on a biomolecular sieving system based on the use of ordered colloidal arrays to define the sieve structure within a microfluidic device. A facile microfluidic colloidal self-assembly strategy has been developed to create ordered, robust, three-dimensional nanofluidic sieves within microfluidic devices, with which fast separation of DNA and proteins of a wide size range was achieved. Compared to conventional colloidal deposition procedures, such as vertical deposition, this approach features much faster assembling speed, the absence of drying-caused cracks that may jeopardize the separation performance, and better flexibility to couple with current microfabrication techniques. The flexibility of pore size enabled by this methodology provides separation of biomolecules with a wide size distribution, ranging from proteins (20-200 kDa) to dsDNA (0.05-50 kbp). Under moderate electric fields, complete separation can be finished in minutes, with separation efficiency comparable to gel/polymer-filled or micro-/nanofabricated microsystems. To our knowledge, this is the first demonstration of size separation of biomolecules within self-assembled ordered colloidal lattices embedded within a microfluidic system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extra-Large-Pore Zeolites with Two-Dimensional Channels Formed by 14 and 12 Rings
Paillaud, J.-L., Harbuzaru, B., Patarin, J., & Bats, N. (2004) · Science · doi:10.1126/science.1098242 · Cited by 355
Cited by
Advances in Colloidal Assembly: The Design of Structure and Hierarchy in Two and Three Dimensions
Vogel, N., Retsch, M., Fustin, C.-A., del Campo, A., & Jonas, U. (2015) · Chemical Reviews · doi:10.1021/cr400081d · Cited by 767
Ultrasensitive detection of circulating exosomes with a 3D-nanopatterned microfluidic chip
Zhang, P., Zhou, X., He, M., Shang, Y., Tetlow, A. L., Godwin, A. K., & Zeng, Y. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0356-9 · Cited by 554
Self-citationMicrofluidics: Applications for analytical purposes in chemistry and biochemistry
Ohno, K., Tachikawa, K., & Manz, A. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800121 · Cited by 398
Molecular sieving using nanofilters: Past, present and future
Han, J., Fu, J., & Schoch, R. B. (2008) · Lab Chip · doi:10.1039/b714128a · Cited by 293
Review article: Fabrication of nanofluidic devices
Duan, C., Wang, W., & Xie, Q. (2013) · Biomicrofluidics · doi:10.1063/1.4794973 · Cited by 274
Metadata
- Authors
- Zeng, Y., & Harrison, D. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-02-16
- Volume
- 79
- Issue
- 6
- Pages
- 2289-2295
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2044149771
- Cited by
- 181
- References
- 1
- FWCI
- 12.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.