Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Electrochemical Immunosensor Using p-Aminophenol Redox Cycling by Hydrazine Combined with a Low Background Current

Das, Jagotamoy, Jo, Kyungmin, Lee, Jae Wook, Yang, Haesik·2007·Analytical Chemistry

Abstract

Signal amplification and noise reduction are crucial for obtaining low detection limits in biosensors. Here, we present an electrochemical immunosensor in which the signal amplification is achieved using p-aminophenol (AP) redox cycling by hydrazine, and the noise level is reduced by implementing a low background current. The redox cycling is obtained in a simple one-electrode, one-enzyme format. In a sandwich-type heterogeneous immunosensor for mouse IgG, an alkaline phosphatase label converts p-aminophenyl phosphate into AP for 10 min. This generated AP is electrooxidized at an indium tin oxide (ITO) electrode modified with a partially ferrocenyl-tethered dendrimer (Fc-D). The oxidized product, p-quinone imine (QI), is reduced back to AP by hydrazine, and then AP is electrooxidized again to QI, resulting in redox cycling. Moreover, hydrazine protects AP from oxidation by air, enabling long incubation times. The small amount of ferrocene in a 0.5% Fc-D-modified ITO electrode, where 0.5% represents the ratio of ferrocene groups to dendrimer amines, results in a low background current, and this electrode exhibits high electron-mediating activity for AP oxidation. Moreover, there is insignificant hydrazine electrooxidation on this electrode, which also results in a low background current. The detection limit of the immunosensor using a 0.5% Fc-D-modified electrode is 2 orders of magnitude lower than that of a 20% Fc-D-modified electrode (10 pg/mL vs 1 ng/mL). Furthermore, the presence of hydrazine reduces the detection limit by an additional 2 orders of magnitude (100 fg/mL vs 10 pg/mL). These results indicate that the occurrence of redox cycling combined with a low background current yields an electrochemical immunosensor with a very low detection limit (100 fg/mL). Mouse IgG could be detected at concentrations ranging from 100 fg/mL to 100 microg/mL (i.e., 9 orders of magnitude) in a single assay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac062291l

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Metadata

Authors
Das, J., Jo, K., Lee, J. W., & Yang, H.
Venue
Analytical Chemistry
Published
2007-02-21
Volume
79
Issue
7
Pages
2790-2796
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2011725306
Cited by
167
References
1
FWCI
12.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.