The DOI matches its Crossref record.
Ultrasensitive Pb2+ Detection by Glutathione-Capped Quantum Dots
Abstract
Water-soluble and stable quantum dots (QDs), CdTe and CdZnSe, are applied for ultrasensitive Pb(2+) detection. These QDs are capped with glutathione (GSH) shells. GSH and its polymeric form, phytochelatin, are employed by nature to detoxify heavy metal ions. As a result of specific interaction, the fluorescence intensity of GSH-capped QDs is selectively reduced in the presence of heavy metal ions such as Pb(2+). The detection limit of Pb(2+) is found to be 20 nM due to the superior fluorescence properties of QDs. Detailed studies by spectroscopy, microscopy, and dynamic light scattering show that competitive GSH binding of Pb(2+) with the QD core changed both the surface and photophysical properties of the QDs. Fluorescence of QDs is quenched, and QD aggregation occurs. Coupling the GSH-capped QDs with a high-throughput detection system, we have developed a simple scheme for quick and ultrasensitive Pb(2+) detection without the need for additional electronic devices. In the presence of ionic mixtures, our system is still capable of Pb(2+) detection with a detection limit as low as 40 nM. The system only becomes less sensitive when the ionic mixture is present at a very high concentration (i.e., > or =50 microM).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhang, L., Zhang, Z.-Y., Liang, R.-P., Li, Y.-H., & Qiu, J.-D. (2014) · Analytical Chemistry · doi:10.1021/ac500289c · Cited by 382
Colorimetric Detection of Pb2+ Using Glutathione Functionalized Gold Nanoparticles
Chai, F., Wang, C., Wang, T., Li, L., & Su, Z. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am100107k · Cited by 375
Xu, S., Lu, H., Li, J., Song, X., Wang, A., Chen, L., & Han, S. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am4022076 · Cited by 293
Fluorescence detection of pesticides using quantum dot materials – A review
Nsibande, S. A., & Forbes, P. B. C. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.10.002 · Cited by 283
Europium-Doped Lead-Free Cs 3 Bi 2 Br 9 Perovskite Quantum Dots and Ultrasensitive Cu 2+ Detection
Ding, N., Zhou, D., Pan, G., Xu, W., Chen, X., Li, D., Zhang, X., Zhu, J., Ji, Y., & Song, H. (2019) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.9b00038 · Cited by 171
Metadata
- Authors
- Mohamed Ali, E., Zheng, Y., Yu, H.-H., & Ying, J. Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-11-16
- Volume
- 79
- Issue
- 24
- Pages
- 9452-9458
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2060173655
- Cited by
- 291
- References
- 0
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasensitive Pb2+ Detection by Glutathione-Capped Quantum Dots. https://app.cochat.ai/papers/10.1021/ac071074x
- The paper
- Mohamed Ali, E., Zheng, Y., Yu, H.-H., & Ying, J. Y. (2007). Ultrasensitive Pb2+ Detection by Glutathione-Capped Quantum Dots. Analytical Chemistry. https://doi.org/10.1021/ac071074x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.