The DOI matches its Crossref record.
Quantum Dot-Based Immunochromatographic Fluorescent Biosensor for Biomonitoring Trichloropyridinol, a Biomarker of Exposure to Chlorpyrifos
Abstract
A novel and portable fluorescent sensor that integrates an immunochromatographic test strip assay (ITSA) with a quantum dot (QD) label and a test strip reader was described in this study for simple, rapid, and sensitive biomonitoring of an organophosphorus pesticide metabolite. The principle of this sensor is based on a competitive immunoreaction that was performed on an immunochromatographic test strip, where analytes compete with competitors (QD-conjugated analogs) to bind to antibodies on a test zone. Captured QDs serve as signal vehicles for fluorescent readout. In this work, 3,5,6-trichloropyridinol (TCP) is used as a model analyte to demonstrate the performance of the immunosensor. QD-TCP conjugates were synthesized and characterized with X-ray photoelectron spectroscopy (XPS) and fluorescence spectroscopy. Some parameters (e.g., the amount of QD-modified TCP and immunoreaction time) that govern sensitivity and reproducibility of ITSA were optimized. Under optimal conditions, the sensor has a wide dynamic range and is capable of detecting a minimum 1.0 ng/mL TCP standard analyte in 15 min. The sensor has been successfully applied for detection of TCP spiked in rat plasma with average recovery of 102.0%. Results demonstrate that this sensor provides a rapid, clinically accurate, and quantitative tool for TCP detection and shows great promise for in-field and point-of-care (POC) quantitative testing and screening for metabolite biomarkers, e.g., TCP, for humans exposed to pesticides.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741
Self-citationPoint of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Nanomaterials for Sensing and Destroying Pesticides
Aragay, G., Pino, F., & Merkoçi, A. (2012) · Chemical Reviews · doi:10.1021/cr300020c · Cited by 573
Huang, X., Aguilar, Z. P., Xu, H., Lai, W., & Xiong, Y. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.032 · Cited by 499
Recent advances in electrochemical biosensors based on graphene two-dimensional nanomaterials
Song, Y., Luo, Y., Zhu, C., Li, H., Du, D., & Lin, Y. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.002 · Cited by 390
Self-citationReview of optical sensors for pesticides
Yan, X., Li, H., & Su, X. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.03.004 · Cited by 385
Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.048 · Cited by 373
Functionalized Quantum Dots for Biosensing and Bioimaging and Concerns on Toxicity
Wang, Y., Hu, R., Lin, G., Roy, I., & Yong, K.-T. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am302030a · Cited by 332
Zhang, W., Asiri, A. M., Liu, D., Du, D., & Lin, Y. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.10.007 · Cited by 270
Self-citation
Metadata
- Authors
- Zou, Z., Du, D., Wang, J., Smith, J. N., Timchalk, C., Li, Y., & Lin, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-05-27
- Volume
- 82
- Issue
- 12
- Pages
- 5125-5133
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2072079539
- Cited by
- 187
- References
- 0
- FWCI
- 10.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.