The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rolling Circle Amplification Combined with Gold Nanoparticle Aggregates for Highly Sensitive Identification of Single-Nucleotide Polymorphisms
Abstract
A highly sensitive and specific colorimetry-based rolling circle amplification (RCA) assay method for single-nucleotide polymorphism genotyping has been developed. A circular template is generated by ligation upon the recognition of a point mutation on DNA targets. An RCA amplification is then initiated using the circular template in the presence of Phi29 polymerase. The RCA product can be digested by a restricting endonuclease, and the cleaved DNA fragments can mediate the aggregation of gold nanoparticle-tagged DNA probes. This causes a colorimetric change of the solution as the indicator of the mutation occurrence, which can be detected using UV-vis spectroscopy or viewed by naked eyes. On the basis of the high amplification efficiency of Phi29 polymerase, a mutated target of approximately 70 fM can be detected in this assay. In addition, the protection of the circle template using phosphorothioated nucleotides allows the digestion reaction to be performed simultaneously in RCA. Moreover, DNA ligase offers high fidelity in distinguishing the mismatched bases at the ligation site, resulting in positive detection of mutant targets even when the ratio of the wild-type to the mutant is 10,000:1. The developed RCA-based colorimetric detection scheme was demonstrated for SNP typing of beta-thalassemia gene at position -28 in genomic DNA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BEAMing up for detection and quantification of rare sequence variants
Li, M., Diehl, F., Dressman, D., Vogelstein, B., & Kinzler, K. W. (2006) · Nature Methods · doi:10.1038/nmeth850 · Cited by 261
Cited by
Noble Metal Nanoparticles for Biosensing Applications
Doria, G., Conde, J., Veigas, B., Giestas, L., Almeida, C., Assunção, M., Rosa, J., & Baptista, P. V. (2012) · Sensors · doi:10.3390/s120201657 · Cited by 708
Deng, R., Tang, L., Tian, Q., Wang, Y., Lin, L., & Li, J. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201309388 · Cited by 450
Self-citationStrategies for enhancing the sensitivity of plasmonic nanosensors
Guo, L., Jackman, J. A., Yang, H.-H., Chen, P., Cho, N.-J., & Kim, D.-H. (2015) · Nano Today · doi:10.1016/j.nantod.2015.02.007 · Cited by 415
Gold nanoparticle-based signal amplification for biosensing
Cao, X., Ye, Y., & Liu, S. (2011) · Analytical Biochemistry · doi:10.1016/j.ab.2011.05.027 · Cited by 393
Guo, L., Xu, Y., Ferhan, A. R., Chen, G., & Kim, D.-H. (2013) · Journal of the American Chemical Society · doi:10.1021/ja405371g · Cited by 342
Synthesis, Characterization, and Applications of Metal Nanoparticles
Shnoudeh, A. J., Hamad, I., Abdo, R. W., Qadumii, L., Jaber, A. Y., Surchi, H. S., & Alkelany, S. Z. (2019) · Biomaterials and Bionanotechnology · doi:10.1016/b978-0-12-814427-5.00015-9 · Cited by 309
Shen, J., Li, Y., Gu, H., Xia, F., & Zuo, X. (2014) · Chemical Reviews · doi:10.1021/cr300248x · Cited by 273
Metadata
- Authors
- Li, J., Deng, T., Chu, X., Yang, R., Jiang, J., Shen, G., & Yu, R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-01
- Volume
- 82
- Issue
- 7
- Pages
- 2811-2816
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2017647887
- Cited by
- 210
- References
- 1
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.