The DOI matches its Crossref record.
Versatile Immunosensor Using a Quantum Dot Coated Silica Nanosphere as a Label for Signal Amplification
Abstract
A versatile immunosensor using a CdTe quantum dots (QDs) coated silica nanosphere (Si/QD) as a label was proposed for ultrasensitive detection of a biomarker. In this approach, silica nanospheres with good monodispersity and uniform structure were employed as the carrier for immobilization of QDs and antibodies. Rabit IgG served as a model protein to demonstrate the performance of the immunosensor. Goat antirabbit IgG antibody was covalently bound to CdTe QDs on the surface of silica nanospheres. CdTe QDs coated with a silica nanosphere label (Si/QD/Ab2) were attached onto the gold electrode surface through a subsequent "sandwich" immunoreaction. This reaction was confirmed by scanning electron microscopic (SEM) and fluorescence microscopic images. Due to signal amplification from the high loading of CdTe QDs, 6.6- and 5.9-fold enhancements in electrochemiluminescent (ECL) and square-wave voltammetric (SWV) signals for IgG detection were achieved compared to the unamplified method. The detection limits for IgG were 1.3 and 0.6 pg mL(-1) for ECL and SWV measurements, respectively. The resulting versatile immunosensor possesses high sensitivity, satisfactory reproducibility and regeneration, and good precision. This simple and specific strategy has vast potential to be used in other biological assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: A review
Pei, X., Zhang, B., Tang, J., Liu, B., Lai, W., & Tang, D. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.10.060 · Cited by 454
Wu, P., Hou, X., Xu, J.-J., & Chen, H.-Y. (2014) · Chemical Reviews · doi:10.1021/cr400710z · Cited by 337
Razmi, H., & Mohammad-Rezaei, R. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.09.009 · Cited by 325
Bifunctional silica nanoparticles for the exploration of biofilms of Pseudomonas aeruginosa
Mauline, L., Gressier, M., Roques, C., Hammer, P., Ribeiro, S. J. L., Caiut, J. M. A., & Menu, M.-J. (2013) · Biofouling · doi:10.1080/08927014.2013.798866 · Cited by 17
Metadata
- Authors
- Qian, J., Zhang, C., Cao, X., & Liu, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-07-02
- Volume
- 82
- Issue
- 15
- Pages
- 6422-6429
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1993089026
- Cited by
- 167
- References
- 0
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.