The DOI matches its Crossref record.
Real-Time Potentiometric Detection of Bacteria in Complex Samples
Open accessAbstract
Detecting and identifying pathogen bacteria is essential to ensure quality at all stages of the food chain and to diagnose and control microbial infections. Traditional detection methods, including those based on cell culturing, are tedious and time-consuming, and their further application in real samples generally implies more complex pretreatment steps. Even though state-of-the-art techniques for detecting microorganisms enable the quantification of very low concentrations of bacteria, to date it has been difficult to obtain successful results in real samples in a simple, reliable, and rapid manner. In this Article, we demonstrate that the label-free detection and identification of living bacteria in real samples can be carried out in a couple of minutes and in a direct, simple, and selective way at concentration levels as low as 6 colony forming units/mL (CFU) in complex matrices such as milk or 26 CFU/mL in apple juice where the pretreatment step of samples is extremely easy. We chose Escherichia coli ( E. coli ) CECT 675 cells as a model organism as a nonpathogenic surrogate for pathogenic E. coli O157:H7 to test the effectiveness of a potentiometric aptamer-based biosensor. This biosensor uses single-walled carbon nanotubes (SWCNT) as excellent ion-to-electron transducers and covalently immobilized aptamers as biorecognition elements. The selective aptamer-target interaction significantly changes the electrical potential, thus allowing for both interspecies and interstrain selectivity and enabling the direct detection of the target. This technique is therefore a powerful tool for the immediate identification and detection of microorganisms. We demonstrate the highly selective detection of living bacteria with an immediate linear response of up to 10(4) CFU/mL. The biosensor can be easily built and used, is regenerated without difficulty, and can be used at least five times with no loss in the minimum amount of detected bacteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Aptamer in Bioanalytical Applications
Iliuk, A. B., Hu, L., & Tao, W. A. (2011) · Analytical Chemistry · doi:10.1021/ac201057w · Cited by 762
Nanotechnologies in Food Science: Applications, Recent Trends, and Future Perspectives
Nile, S. H., Baskar, V., Selvaraj, D., Nile, A., Xiao, J., & Kai, G. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-0383-9 · Cited by 631
Seok Kim, Y., Ahmad Raston, N. H., & Bock Gu, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.040 · Cited by 442
Biosensors as innovative tools for the detection of food borne pathogens
Arora, P., Sindhu, A., Dilbaghi, N., & Chaudhury, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.06.002 · Cited by 350
Impedance-Based Detection of Bacteria
Furst, A. L., & Francis, M. B. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00381 · Cited by 321
Ronspees, A. T., & Thorgaard, S. N. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.05.006 · Cited by 46
Redox activity of single bacteria revealed by electrochemical collision technique
Chen, Y., Wang, D., Liu, Y., Gao, G., & Zhi, J. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112914 · Cited by 34
Metadata
- Authors
- Zelada-Guillén, G. A., Bhosale, S. V., Riu, J., & Rius, F. X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-20
- Volume
- 82
- Issue
- 22
- Pages
- 9254-9260
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2317948651
- Cited by
- 202
- References
- 0
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.