The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Detection of Mercury Ion by Infrared Fluorescent Protein and Its Hydrogel-Based Paper Assay
Abstract
Mercury is a highly hazardous and widespread pollutant with bioaccumulative properties. Novel approaches that meet the criteria of desired selectivity, high sensitivity, good biocompatibility, and low background interference in natural settings are continuously being explored. We herein describe a new strategy utilizing the combination of infrared fluorescent protein (IFP) and its chromophore as an infrared fluorescence probe for mercury ion (Hg(II)) detection. Hg(II) has been validated to have specific binding affinity to a cysteine residue (C24) of IFP, thereby inhibiting the conjugation of IFP chromophore biliverdin (BV) to C24 and "turning off" the infrared emission of IFP. The IFP/BV sensor has high selectivity toward Hg(II) among other metal ions over a broad pH range. The in vitro detection limit was determined to be less than 50 nM. As a genetically encoded probe, we demonstrate the IFP/BV sensor can serve as a tool to detect Hg(II) in living organisms or tissues. Moreover, we have exploited a protein-agarose hydrogel-based paper assay to immobilize IFP for detection of Hg(II) in a portable and robust fashion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hazards of heavy metal contamination
Järup, L. (2003) · British Medical Bulletin · doi:10.1093/bmb/ldg032 · Cited by 6,508
Cited by
Fluorescent and colorimetric sensors for detection of lead, cadmium, and mercury ions
Kim, H. N., Ren, W. X., Kim, J. S., & Yoon, J. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15245a · Cited by 2,253
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Greenwald, E. C., Mehta, S., & Zhang, J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00333 · Cited by 495
A Self‐Powered Triboelectric Nanosensor for Mercury Ion Detection
Lin, Z., Zhu, G., Zhou, Y. S., Yang, Y., Bai, P., Chen, J., & Wang, Z. L. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201300437 · Cited by 371
Metadata
- Authors
- Gu, Z., Zhao, M., Sheng, Y., Bentolila, L. A., & Tang, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-02-16
- Volume
- 83
- Issue
- 6
- Pages
- 2324-2329
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2028277176
- Cited by
- 170
- References
- 1
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Mercury Ion by Infrared Fluorescent Protein and Its Hydrogel-Based Paper Assay. https://app.cochat.ai/papers/10.1021/ac103236g
- The paper
- Gu, Z., Zhao, M., Sheng, Y., Bentolila, L. A., & Tang, Y. (2011). Detection of Mercury Ion by Infrared Fluorescent Protein and Its Hydrogel-Based Paper Assay. Analytical Chemistry. https://doi.org/10.1021/ac103236g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.