The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Highly Sensitive Immunoassay Based on Immunogold−Silver Amplification and Inductively Coupled Plasma Mass Spectrometric Detection
Abstract
In this work, we demonstrated a highly sensitive inductively coupled plasma mass spectrometric (ICPMS) method for the determination of human carcinoembryonic antigen (CEA), which combined the inherent high sensitivity of elemental mass spectrometric measurement with the signal amplification of catalytic silver deposition on immunogold tags. The silver amplification procedure was easy to handle and required cheap reagents, and the sensitivity was greatly enhanced to 60-fold after a 15 min silver amplification procedure. The experimental conditions, including detection of gold and silver by ICPMS, immunoassay parameters, silver amplification parameters, analytical performance, and clinical serum samples analysis, were investigated. The ICPMS Ag signal intensity depends linearly on the logarithm of the concentration of human CEA over the range of 0.07-1000 ng mL(-1) with a limit of detection (LOD, 3σ) of 0.03 ng mL(-1) (i.e., 0.15 pM). The LOD of the proposed method is around 2 orders of magnitude lower than that by the widely used enzyme-linked immunosorbent assay (ELISA) and 1 order of magnitude lower than that by clinical routine chemiluminescence immunoassay (CLIA) or time-resolved fluoroimmunoassay (TRFIA) and conventional ICPMS immunoassay. The present strategy was applied to the determination of human CEA in clinical human serum samples, and the results were in good agreement with those obtained by chemiluminescence immunoassay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of individual endogenous protein complexes in situ by proximity ligation
Söderberg, O., Gullberg, M., Jarvius, M., Ridderstråle, K., Leuchowius, K.-J., Jarvius, J., Wester, K., Hydbring, P., Bahram, F., Larsson, L.-G., et al. (2006) · Nature Methods · doi:10.1038/nmeth947 · Cited by 2,419
Bandura, D. R., Baranov, V. I., Ornatsky, O. I., Antonov, A., Kinach, R., Lou, X., Pavlov, S., Vorobiev, S., Dick, J. E., & Tanner, S. D. (2009) · Analytical Chemistry · doi:10.1021/ac901049w · Cited by 1,295
Cited by
Wilson, D. H., Rissin, D. M., Kan, C. W., Fournier, D. R., Piech, T., Campbell, T. G., Meyer, R. E., Fishburn, M. W., Cabrera, C., Patel, P. P., et al. (2016) · SLAS Technology · doi:10.1177/2211068215589580 · Cited by 470
Metadata
- Authors
- Liu, R., Liu, X., Tang, Y., Wu, L., Hou, X., & Lv, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-02-24
- Volume
- 83
- Issue
- 6
- Pages
- 2330-2336
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2331965236
- Cited by
- 160
- References
- 2
- FWCI
- 14.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive Immunoassay Based on Immunogold−Silver Amplification and Inductively Coupled Plasma Mass Spectrometric Detection. https://app.cochat.ai/papers/10.1021/ac103265z
- The paper
- Liu, R., Liu, X., Tang, Y., Wu, L., Hou, X., & Lv, Y. (2011). Highly Sensitive Immunoassay Based on Immunogold−Silver Amplification and Inductively Coupled Plasma Mass Spectrometric Detection. Analytical Chemistry. https://doi.org/10.1021/ac103265z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.