Fully Automated Dynamic In-Syringe Liquid-Phase Microextraction and On-Column Derivatization of Carbamate Pesticides with Gas Chromatography/Mass Spectrometric Analysis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A new fully automated dynamic in-syringe liquid-phase microextraction (LPME) and on-column derivatization approach, with gas chromatography/mass spectrometric (GC/MS) analysis, was developed to determine carbamate pesticides from water samples. With the use of a CTC CombiPal autosampler and its associated Cycle Composer software, a sample preparation-GC/MS method was enabled that allowed sample extraction, extract injection, and analyte derivatization to be carried out completely automatically. Optimization of extraction parameters was carried out by orthogonal array design which required a minimum of 16 experiments; the entire set of experiments was performed completely automatically and consecutively without any human intervention. Low limits of detection ranging from 0.05 to 0.1 μg/L were achieved for the carbamates. Effective enrichment of the analytes at a low concentration of 0.01 mg/L was also achieved (enrichment factors of between 57 and 138). The precision of the optimized method was satisfactory, with relative standard deviations of <6.0% (n = 6). High relative recoveries of between 81 and 125% were obtained when the method was applied to the analysis of real water samples, indicating that the sample matrix had little effect on the developed method. This automated dynamic in-syringe LPME approach demonstrated the feasibility of a complete analytical system comprising sample preparation and GC/MS that might be operated onsite, fully automatically without human intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Lee, J., Lee, H. K., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.050 · Cited by 398
Self-citation
Cited by
Advances in solvent-microextraction techniques
Kokosa, J. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.09.020 · Cited by 225
Tang, S., Qi, T., Ansah, P. D., Nalouzebi Fouemina, J. C., Shen, W., Basheer, C., & Lee, H. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.09.016 · Cited by 195
Self-citationDeep eutectic solvent-based dispersive liquid-liquid microextraction
Farajzadeh, M. A., Afshar Mogaddam, M. R., & Aghanassab, M. (2016) · Analytical Methods · doi:10.1039/c5ay03189c · Cited by 141
Kokosa, J. M. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.019 · Cited by 137
Chu, S.-P., Tseng, W.-C., Kong, P.-H., Huang, C.-K., Chen, J.-H., Chen, P.-S., & Huang, S.-D. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.04.015 · Cited by 31
Metadata
- Authors
- Lee, J., & Lee, H. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-07-28
- Volume
- 83
- Issue
- 17
- Pages
- 6856-6861
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2314990874
- Cited by
- 103
- References
- 2
- FWCI
- 9.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.