The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Hearing What You Cannot See and Visualizing What You Hear: Interpreting Quartz Crystal Microbalance Data from Solvated Interfaces
Open accessAbstract
Over the last 2 decades, the quartz crystal microbalance (QCM or QCM-D) has emerged as a versatile tool for investigating soft and solvated interfaces between solid surfaces and bulk liquids because it can provide a wealth of information about key structural and functional parameters of these interfaces. In this Feature, we offer QCM users a set of guidelines for interpretation and quantitative analysis of QCM data based on a synthesis of well-established concepts rooted in rheological research of the last century and of new results obtained in the last several years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Viscoelastic Properties of Polymers
Ferry, J. D., & Myers, H. S. (1961) · Journal of The Electrochemical Society · doi:10.1149/1.2428174 · Cited by 13,487
Viscoelastic Properties of Polymers
Jones, W. M. (1981) · Journal of Non-Newtonian Fluid Mechanics · doi:10.1016/0377-0257(81)80036-5 · Cited by 11,092
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
The use of quarts oscillators for weighing thin layers and for microweighing
Sauerbrey, G., & Sauerbrey, G. (1959) · Medical Entomology and Zoology · Cited by 4,456
Present and future of surface plasmon resonance biosensors
Homola, J. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2101-0 · Cited by 2,321
Ellipsometry and Polarized Light
Cox, L. J. (1978) · Optica Acta: International Journal of Optics · doi:10.1080/713819761 · Cited by 1,897
Voinova, M. V., Rodahl, M., Jonson, M., & Kasemo, B. (1999) · Physica Scripta · doi:10.1238/physica.regular.059a00391 · Cited by 1,587
Optical Properties of Thin Solid Films
Heavens, O. S., & Singer, S. F. (1956) · Physics Today · doi:10.1063/1.3059910 · Cited by 1,370
Rodahl, M., Höök, F., Krozer, A., Brzezinski, P., & Kasemo, B. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145396 · Cited by 1,296
Optical Properties of Thin Solid Films
Heavens, O. S. (1965) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,182
Höök, F., Kasemo, B., Nylander, T., Fant, C., Sott, K., & Elwing, H. (2001) · Analytical Chemistry · doi:10.1021/ac0106501 · Cited by 1,162
Marx, K. A. (2003) · Biomacromolecules · doi:10.1021/bm020116i · Cited by 1,143
Formation of Solid-Supported Lipid Bilayers: An Integrated View
Richter, R. P., Bérat, R., & Brisson, A. R. (2006) · Langmuir · doi:10.1021/la052687c · Cited by 1,126
Self-citationOptical properties of thin solid films
Jolliffee, K. H. (1954) · Vacuum · doi:10.1016/0042-207x(54)90274-2 · Cited by 1,095
Kasemo, B. (2002) · Surface Science · doi:10.1016/s0039-6028(01)01809-x · Cited by 1,079
Surface Specific Kinetics of Lipid Vesicle Adsorption Measured with a Quartz Crystal Microbalance
Keller, C. A., & Kasemo, B. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)74057-3 · Cited by 1,010
Piezoelectric Crystals and Their Applications to Ultrasonics
Mason, W. P., & Baerwald, H. (1951) · Physics Today · doi:10.1063/1.3067231 · Cited by 933
Surface acoustic wave biosensors: a review
Länge, K., Rapp, B. E., & Rapp, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1911-5 · Cited by 806
The Density and Refractive Index of Adsorbing Protein Layers
Vörös, J. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.030072 · Cited by 752
Buildup Mechanism for Poly(l-lysine)/Hyaluronic Acid Films onto a Solid Surface
Picart, C., Lavalle, P., Hubert, P., Cuisinier, F. J. G., Decher, G., Schaaf, P., & Voegel, J.-C. (2001) · Langmuir · doi:10.1021/la010848g · Cited by 695
Höök, F., Vörös, J., Rodahl, M., Kurrat, R., Böni, P., Ramsden, J. J., Textor, M., Spencer, N. D., Tengvall, P., Gold, J., et al. (2002) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(01)00236-3 · Cited by 671
Self-Assembled Nanostructured Materials
Fendler, J. H. (1996) · Chemistry of Materials · doi:10.1021/cm960116n · Cited by 584
Cho, N.-J., Frank, C. W., Kasemo, B., & Höök, F. (2010) · Nature Protocols · doi:10.1038/nprot.2010.65 · Cited by 542
In Situ Interfacial Mass Detection with Piezoelectric Transducers
Ward, M. D., & Buttry, D. A. (1990) · Science · doi:10.1126/science.249.4972.1000 · Cited by 525
Fusetani, N. (2004) · Natural Product Reports · doi:10.1039/b302231p · Cited by 416
Reimhult, E., Larsson, C., Kasemo, B., & Höök, F. (2004) · Analytical Chemistry · doi:10.1021/ac0492970 · Cited by 300
Johannsmann, D. (2008) · Physical Chemistry Chemical Physics · doi:10.1039/b803960g · Cited by 297
Self-citationMeasurement of Shear Elasticity and Viscosity of Liquids at Ultrasonic Frequencies
Mason, W. P., Baker, W. O., Mcskimin, H. J., & Heiss, J. H. (1949) · Physical Review · doi:10.1103/physrev.75.936 · Cited by 266
Schumacher, R. (1990) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199003293 · Cited by 266
Surface acoustic wave sensors in the bioanalytical field: Recent trends and challenges
Gronewold, T. M. A. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.09.056 · Cited by 250
Determination of complex shear modulus with thickness shear mode resonators
Lucklum, R., Behling, C., Cernosek, R. W., & Martin, S. J. (1997) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/30/3/006 · Cited by 183
A sensitive new method for the determination of adhesive bonding between a particle and a substrate
Dybwad, G. L. (1985) · Journal of Applied Physics · doi:10.1063/1.335874 · Cited by 182
Swelling of a polymer brush probed with a quartz crystal resonator
Domack, A., Prucker, O., Rühe, J., & Johannsmann, D. (1997) · Physical Review E · doi:10.1103/physreve.56.680 · Cited by 181
Self-citationInfluence of Roughness on the Admittance of the Quartz Crystal Microbalance Immersed in Liquids
Daikhin, L., Gileadi, E., Katz, G., Tsionsky, V., Urbakh, M., & Zagidulin, D. (2002) · Analytical Chemistry · doi:10.1021/ac0107610 · Cited by 172
Malmström, J., Agheli, H., Kingshott, P., & Sutherland, D. S. (2007) · Langmuir · doi:10.1021/la701233y · Cited by 153
Zhou, T., Marx, K. A., Warren, M., Schulze, H., & Braunhut, S. J. (2000) · Biotechnology Progress · doi:10.1021/bp000003f · Cited by 142
Effect of Adsorbed Layer Surface Roughness on the QCM-D Response: Focus on Trapped Water
Macáková, L., Blomberg, E., & Claesson, P. M. (2007) · Langmuir · doi:10.1021/la7014308 · Cited by 142
The Quartz Crystal Microbalance as a Novel Means to Study Cell-Substrate Interactions In Situ
Wegener, J., Janshoff, A., & Steinem, C. (2001) · Cell Biochemistry and Biophysics · doi:10.1385/cbb:34:1:121 · Cited by 111
Interfacial re-arrangement in initial microbial adhesion to surfaces
Busscher, H. J., Norde, W., Sharma, P. K., & van der Mei, H. C. (2010) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2010.05.014 · Cited by 94
Marxer, C. G., Coen, M. C., Greber, T., Greber, U. F., & Schlapbach, L. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2080-1 · Cited by 82
Membrane-Grafted Hyaluronan Films: A Well-Defined Model System of Glycoconjugate Cell Coats
Richter, R. P., Hock, K. K., Burkhartsmeyer, J. M., Boehm, H., Bingen, P., Wang, G., Steinmetz, N. F., Evans, D. J., & Spatz, J. P. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068768s · Cited by 69
Self-citation
Cited by
Nanoplasmonic sensors for biointerfacial science
Jackman, J. A., Rahim Ferhan, A., & Cho, N.-J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00494f · Cited by 258
Relevance of glycosylation of S-layer proteins for cell surface properties
Schuster, B., & Sleytr, U. B. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.03.020 · Cited by 47
Mousseau, F., Oikonomou, E. K., Baldim, V., Mornet, S., & Berret, J.-F. (2018) · Colloids and Interfaces · doi:10.3390/colloids2040050 · Cited by 10
(2017) · PubMed
Metadata
- Authors
- Reviakine, I., Johannsmann, D., & Richter, R. P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-17
- Volume
- 83
- Issue
- 23
- Pages
- 8838-8848
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2079933315
- Cited by
- 871
- References
- 42
- FWCI
- 20.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.