Improving Proteomics Mass Accuracy by Dynamic Offline Lock Mass
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Several methods to obtain low-ppm mass accuracy have been described. In particular, online or offline lock mass approaches can use background ions, produced by electrospray under ambient conditions, as calibrants. However, background ions such as protonated and ammoniated polydimethylcyclosiloxane ions have relatively weak and fluctuating intensity. To address this issue, we implemented dynamic offline lock mass (DOLM). Within every MS1 survey spectrum, DOLM dynamically selected the strongest n background ions for statistical treatments and m/z recalibration. We systematically optimized the mass profile abstraction method to find one single m/z value to represent an ion and the number of calibrants. To assess the influence of the intensity of the analyte ions, we used tandem mass spectroscopy (MS/MS) datasets obtained from MudPIT analyses of two protein samples with different dynamic ranges. DOLM outperformed both external mass calibration and offline lock mass that used predetermined calibrant ions, especially in the low-ppm range. The unique dynamic feature of DOLM was able to adapt to wide variations in calibrant intensities, leading to averaged mass error center at 0.03 ± 0.50 ppm for precursor ions. Such consistently tight mass accuracies meant that a precursor mass tolerance as low as 1.5 ppm could be used to search or filter post-search DOLM-recalibrated MS/MS datasets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graumann, J., Hubner, N. C., Kim, J. B., Ko, K., Moser, M., Kumar, C., Cox, J., Schöler, H., & Mann, M. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700460-mcp200 · Cited by 275
On the Proper Use of Mass Accuracy in Proteomics
Zubarev, R., & Mann, M. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600380-mcp200 · Cited by 165
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Self-citationDynamic RNA acetylation revealed by quantitative cross-evolutionary mapping
Sas-Chen, A., Thomas, J. M., Matzov, D., Taoka, M., Nance, K. D., Nir, R., Bryson, K. M., Shachar, R., Liman, G. L. S., Burkhart, B. W., et al. (2020) · Nature · doi:10.1038/s41586-020-2418-2 · Cited by 336
Self-citationPáez-Moscoso, D. J., Ho, D. V., Pan, L., Hildebrand, K., Jensen, K. L., Levy, M. J., Florens, L., & Baumann, P. (2022) · Nature Communications · doi:10.1038/s41467-022-28545-9 · Cited by 10
Self-citationPáez-Moscoso, D. J., Ho, D. V., Pan, L., Hildebrand, K., Jensen, K. L., Levy, M. J., Florens, L., & Baumann, P. (2021) · doi:10.1101/2021.12.15.472819 · Cited by 2
Self-citation
Metadata
- Authors
- Zhang, Y., Wen, Z., Washburn, M. P., & Florens, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-11-16
- Volume
- 83
- Issue
- 24
- Pages
- 9344-9351
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2065701448
- Cited by
- 44
- References
- 2
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving Proteomics Mass Accuracy by Dynamic Offline Lock Mass. https://app.cochat.ai/papers/10.1021/ac201867h
- The paper
- Zhang, Y., Wen, Z., Washburn, M. P., & Florens, L. (2011). Improving Proteomics Mass Accuracy by Dynamic Offline Lock Mass. Analytical Chemistry. https://doi.org/10.1021/ac201867h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.