The DOI matches its Crossref record.
High-Precision Isothermal Titration Calorimetry with Automated Peak-Shape Analysis
Open accessAbstract
Isothermal titration calorimetry (ITC) is a powerful classical method that enables researchers in many fields to study the thermodynamics of molecular interactions. Primary ITC data comprise the temporal evolution of differential power reporting the heat of reaction during a series of injections of aliquots of a reactant into a sample cell. By integration of each injection peak, an isotherm can be constructed of total changes in enthalpy as a function of changes in solution composition, which is rich in thermodynamic information on the reaction. However, the signals from the injection peaks are superimposed by the stochastically varying time-course of the instrumental baseline power, limiting the precision of ITC isotherms. Here, we describe a method for automated peak assignment based on peak-shape analysis via singular value decomposition in combination with detailed least-squares modeling of local pre- and postinjection baselines. This approach can effectively filter out contributions of short-term noise and adventitious events in the power trace. This method also provides, for the first time, statistical error estimates for the individual isotherm data points. In turn, this results in improved detection limits for high-affinity or low-enthalpy binding reactions and significantly higher precision of the derived thermodynamic parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhao, H., Piszczek, G., & Schuck, P. (2015) · Methods · doi:10.1016/j.ymeth.2014.11.012 · Cited by 347
Self-citationCardiolipin Prevents Membrane Translocation and Permeabilization by Daptomycin
Zhang, T., Muraih, J. K., Tishbi, N., Herskowitz, J., Victor, R. L., Silverman, J., Uwumarenogie, S., Taylor, S. D., Palmer, M., & Mintzer, E. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.m114.554444 · Cited by 162
Choi, E., Kikuchi, S., Gao, H., Brodzik, K., Nassour, I., Yopp, A., Singal, A. G., Zhu, H., & Yu, H. (2019) · Nature Communications · doi:10.1038/s41467-019-09318-3 · Cited by 89
Visualizing RNA conformational and architectural heterogeneity in solution
Ding, J., Lee, Y.-T., Bhandari, Y., Schwieters, C. D., Fan, L., Yu, P., Tarosov, S. G., Stagno, J. R., Ma, B., Nussinov, R., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-36184-x · Cited by 66
The Fab region of IgG impairs the internalization pathway of FcRn upon Fc engagement
Brinkhaus, M., Pannecoucke, E., van der Kooi, E. J., Bentlage, A. E. H., Derksen, N. I. L., Andries, J., Balbino, B., Sips, M., Ulrichts, P., Verheesen, P., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-33764-1 · Cited by 51
Metadata
- Authors
- Keller, S., Vargas, C., Zhao, H., Piszczek, G., Brautigam, C. A., & Schuck, P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-06-05
- Volume
- 84
- Issue
- 11
- Pages
- 5066-5073
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2028556267
- Cited by
- 515
- References
- 0
- FWCI
- 20.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Precision Isothermal Titration Calorimetry with Automated Peak-Shape Analysis. https://app.cochat.ai/papers/10.1021/ac3007522
- The paper
- Keller, S., Vargas, C., Zhao, H., Piszczek, G., Brautigam, C. A., & Schuck, P. (2012). High-Precision Isothermal Titration Calorimetry with Automated Peak-Shape Analysis. Analytical Chemistry. https://doi.org/10.1021/ac3007522
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.