The DOI matches its Crossref record.
Molecular Beacon Lighting up on Graphene Oxide
Abstract
A molecular beacon (MB) is comprised of a fluorophore and a quencher linked by a DNA hairpin. MBs have been widely used for homogeneous DNA detection. In addition to molecular quenchers, many nanomaterials such as graphene oxide (GO) also possess excellent quenching efficiency. Most reported fluorescent sensors relied on DNA probes physisorbed by GO, which may suffer from nonspecific probe displacement and false positive signal. In this work, we report the preparation and characterization of a MB using graphene oxide (GO) as quencher, where an amino and FAM (6-carboxyfluorescein) dual labeled DNA was covalently attached to GO via an amide linkage. A major challenge was to remove noncovalently attached probes due to strong DNA adsorption by GO. While DNA desorption was favored at low salt, high pH, high temperature, and by using organic solvents, the cDNA was required to achieve complete desorption of noncovalently linked DNA probes. The DNA adsorption energy was measured using isothermal titration calorimetry, revealing the heterogeneous nature of GO. The covalent probe has a detection limit of 2.2 nM using a sample volume of 0.05 mL. With a 2 mL sample, the detection limit can reach 150 pM. The covalent probe is highly resistant to nonspecific probe displacement and will find applications in serum and cellular samples where high probe stability is demanded.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhang, X.-L., Zheng, C., Guo, S.-S., Li, J., Yang, H.-H., & Chen, G. (2014) · Analytical Chemistry · doi:10.1021/ac500336f · Cited by 414
Adsorption of DNA onto gold nanoparticles and graphene oxide: surface science and applications
Liu, J. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41186e · Cited by 408
Self-citationSingh, D. P., Herrera, C. E., Singh, B., Singh, S., Singh, R. K., & Kumar, R. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2018.01.004 · Cited by 313
Meng, Y., Liu, P., Zhou, W., Ding, J., & Liu, J. (2018) · ACS Nano · doi:10.1021/acsnano.8b03019 · Cited by 149
Self-citationPhoemphoonthanyakit, S., Seeharaj, P., Damrongsak, P., & Locharoenrat, K. (2019) · Journal of Spectroscopy · doi:10.1155/2019/2853989 · Cited by 20
Metadata
- Authors
- Huang, P.-J. J., & Liu, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-18
- Volume
- 84
- Issue
- 9
- Pages
- 4192-4198
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2313771558
- Cited by
- 163
- References
- 0
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Molecular Beacon Lighting up on Graphene Oxide. https://app.cochat.ai/papers/10.1021/ac300778s
- The paper
- Huang, P.-J. J., & Liu, J. (2012). Molecular Beacon Lighting up on Graphene Oxide. Analytical Chemistry. https://doi.org/10.1021/ac300778s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.