CoChat

Direct Analysis of δ2H and δ18O in Natural and Enriched Human Urine Using Laser-Based, Off-Axis Integrated Cavity Output Spectroscopy

Open access
Berman, Elena S. F., Fortson, Susan L., Snaith, Steven P., Gupta, Manish, Baer, Douglas S., Chery, Isabelle, Blanc, Stephane, Melanson, Edward L., Thomson, Peter J., Speakman, John R. · 2012 · Analytical Chemistry
Cited by 60

The DOI matches its Crossref record.

Abstract

The stable isotopes of hydrogen (δ(2)H) and oxygen (δ(18)O) in human urine are measured during studies of total energy expenditure by the doubly labeled water method, measurement of total body water, and measurement of insulin resistance by glucose disposal among other applications. An ultrasensitive laser absorption spectrometer based on off-axis integrated cavity output spectroscopy was demonstrated for simple and inexpensive measurement of stable isotopes in natural isotopic abundance and isotopically enriched human urine. Preparation of urine for analysis was simple and rapid (approximately 25 samples per hour), requiring no decolorizing or distillation steps. Analysis schemes were demonstrated to address sample-to-sample memory while still allowing analysis of 45 natural or 30 enriched urine samples per day. The instrument was linear over a wide range of water isotopes (δ(2)H = -454 to +1702 ‰ and δ(18)O = -58.3 to +265 ‰). Measurements of human urine were precise to better than 0.65 ‰ 1σ for δ(2)H and 0.09 ‰ 1σ for δ(18)O for natural urines, 1.1 ‰ 1σ for δ(2)H and 0.13 ‰ 1σ for δ(18)O for low enriched urines, and 1.0 ‰ 1σ for δ(2)H and 0.08 ‰ 1σ for δ(18)O for high enriched urines. Furthermore, the accuracy of the isotope measurements of human urines was verified to better than ±0.81 ‰ in δ(2)H and ±0.13 ‰ in δ(18)O (average deviation) against three independent isotope-ratio mass spectrometry laboratories. The ability to immediately and inexpensively measure the stable isotopes of water in human urine is expected to increase the number and variety of experiments which can be undertaken.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac3016642

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 60

Metadata

Authors
Berman, E. S. F., Fortson, S. L., Snaith, S. P., Gupta, M., Baer, D. S., Chery, I., Blanc, S., Melanson, E. L., Thomson, P. J., & Speakman, J. R.
Venue
Analytical Chemistry
Published
2012-11-01
Volume
84
Issue
22
Pages
9768-9773
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2057799307
Cited by
60
References
0
FWCI
0.80
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct Analysis of δ2H and δ18O in Natural and Enriched Human Urine Using Laser-Based, Off-Axis Integrated Cavity Output Spectroscopy. https://app.cochat.ai/papers/10.1021/ac3016642
The paper
Berman, E. S. F., Fortson, S. L., Snaith, S. P., Gupta, M., Baer, D. S., Chery, I., Blanc, S., Melanson, E. L., Thomson, P. J., & Speakman, J. R. (2012). Direct Analysis of δ2H and δ18O in Natural and Enriched Human Urine Using Laser-Based, Off-Axis Integrated Cavity Output Spectroscopy. Analytical Chemistry. https://doi.org/10.1021/ac3016642

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.