Amphipathic Polymers Enable the Study of Functional Membrane Proteins in the Gas Phase
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Membrane proteins are notoriously challenging to analyze using mass spectrometry (MS) because of their insolubility in aqueous solution. Current MS methods for studying intact membrane proteins involve solubilization in detergent. However, detergents can destabilize proteins, leading to protein unfolding and aggregation, or resulting in inactive entities. Amphipathic polymers, termed amphipols, can be used as a substitute for detergents and have been shown to enhance the stability of membrane proteins. Here, we show the utility of amphipols for investigating the structural and functional properties of membrane proteins using electrospray ionization mass spectrometry (ESI-MS). The functional properties of two bacterial outer-membrane β-barrel proteins, OmpT and PagP, in complex with the amphipol A8-35 are demonstrated, and their structural integrities are confirmed in the gas phase using ESI-MS coupled with ion mobility spectrometry (IMS). The data illustrate the power of ESI-IMS-MS in separating distinct populations of amphipathic polymers from the amphipol-membrane complex while maintaining a conformationally "nativelike" membrane protein structure in the gas phase. Together, the data indicate the potential importance and utility of amphipols for the analysis of membrane proteins using MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in the Mass Spectrometry of Membrane Proteins: From Individual Proteins to Intact Complexes
Barrera, N. P., & Robinson, C. V. (2011) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-062309-093307 · Cited by 154
Cited by
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“Nowadays, with the application of alternative solubilization techniques such as Amphipols [48] and Nanodiscs [49], the analysis of membrane proteins by native MS has become more widespread with studies of over 30 membrane proteins/ membrane protein complexes being reported to date.”
BackgroundSelf-citationMass Spectrometry of Protein Complexes: From Origins to Applications
Mehmood, S., Allison, T. M., & Robinson, C. V. (2015) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040214-121732 · Cited by 199
“Despite this, it has been shown to be possible to retain folded conformations of membrane proteins introduced to the mass spectrometer in amphipols (100).”
BackgroundMethodHedges, J. B., Vahidi, S., Yue, X., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac401020s · Cited by 109
Metadata
- Authors
- Leney, A. C., McMorran, L. M., Radford, S. E., & Ashcroft, A. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-10-29
- Volume
- 84
- Issue
- 22
- Pages
- 9841-9847
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1968326351
- Cited by
- 57
- References
- 1
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Amphipathic Polymers Enable the Study of Functional Membrane Proteins in the Gas Phase. https://app.cochat.ai/papers/10.1021/ac302223s
- The paper
- Leney, A. C., McMorran, L. M., Radford, S. E., & Ashcroft, A. E. (2012). Amphipathic Polymers Enable the Study of Functional Membrane Proteins in the Gas Phase. Analytical Chemistry. https://doi.org/10.1021/ac302223s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.