The DOI matches its Crossref record.
Through Bond Energy Transfer: A Convenient and Universal Strategy toward Efficient Ratiometric Fluorescent Probe for Bioimaging Applications
Abstract
Fluorescence resonance energy transfer (FRET) strategy has been widely applied in designing ratiometric probes for bioimaging applications. Unfortunately, for FRET systems, sufficiently large spectral overlap is necessary between the donor emission and the acceptor absorption, which would limit the resolution of double-channel images. The through-bond energy transfer (TBET) system does not need spectral overlap between donor and acceptor and could afford large wavelength difference between the two emissions with improved imaging resolution and higher energy transfer efficiency than that of the classical FRET system. It seems to be more favorable for designing ratiometric probes for bioimaging applications. In this paper, we have designed and synthesized a coumarin-rhodamine (CR) TBET system and demonstrated that TBET is a convenient strategy to design an efficient ratiometric fluorescent bioimaging probe for metal ions. Such TBET strategy is also universal, since no spectral overlap between the donor and the acceptor is necessary, and many more dye pairs than that of FRET could be chosen for probe design. As a proof-of-concept, Hg(2+) was chosen as a model metal ion. By combining TBET strategy with dual-switch design, the proposed sensing platform shows two well-separated emission peaks with a wavelength difference of 110 nm, high energy transfer efficiency, and a large signal-to-background ratio, which affords a high sensitivity for the probe with a detection limit of 7 nM for Hg(2+). Moreover, by employing an Hg(2+)-promoted desulfurization reaction as recognition unit, the probe also shows a high selectivity to Hg(2+). All these unique features make it particularly favorable for ratiometric Hg(2+) sensing and bioimaging applications. It has been preliminarily used for a ratiometric image of Hg(2+) in living cells and practical detection of Hg(2+) in river water samples with satisfying results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Yao, J., Zhang, K., Zhu, H., Ma, F., Sun, M., Yu, H., Sun, J., & Wang, S. (2013) · Analytical Chemistry · doi:10.1021/ac401011r · Cited by 286
Kim, E.-J., Kumar, R., Sharma, A., Yoon, B., Kim, H. M., Lee, H., Hong, K. S., & Kim, J. S. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.009 · Cited by 129
Metadata
- Authors
- Gong, Y.-J., Zhang, X.-B., Zhang, C.-C., Luo, A.-L., Fu, T., Tan, W., Shen, G.-L., & Yu, R.-Q.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-12-04
- Volume
- 84
- Issue
- 24
- Pages
- 10777-10784
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2331972087
- Cited by
- 171
- References
- 0
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Through Bond Energy Transfer: A Convenient and Universal Strategy toward Efficient Ratiometric Fluorescent Probe for Bioimaging Applications. https://app.cochat.ai/papers/10.1021/ac302762d
- The paper
- Gong, Y.-J., Zhang, X.-B., Zhang, C.-C., Luo, A.-L., Fu, T., Tan, W., Shen, G.-L., & Yu, R.-Q. (2012). Through Bond Energy Transfer: A Convenient and Universal Strategy toward Efficient Ratiometric Fluorescent Probe for Bioimaging Applications. Analytical Chemistry. https://doi.org/10.1021/ac302762d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.