The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dual-Signal Amplification Strategy for Ultrasensitive Photoelectrochemical Immunosensing of α-Fetoprotein
Abstract
An ultrasensitive photoelectrochemical immunoassay of cancer biomarker α-fetoprotein (AFP) is proposed that uses titanium dioxide (TiO(2)) coupled with AFP-CdTe-GOx bioconjugate, which featured AFP antigen and glucose oxidase (GOx) labels linked to CdTe quantum dots (QDs) for signal amplification. The synthesized CdTe QDs yielded a homogeneous and narrow size distribution, which allowed the binding of AFP and GOx on CdTe QDs. Greatly enhanced sensitivity for AFP came from a dual signal amplification strategy. First, an effective matching of energy levels between the conduction bands of CdTe QDs and TiO(2) allowed for fast electron injection from excited CdTe QDs to TiO(2) upon irradiation, which reduced the recombination process of electron-hole pairs and prompted photoelectrochemical performance. Second, GOx enzyme could catalyze glucose to produce H(2)O(2), which acted as a sacrificial electron donor to scavenge the photogenerated holes in the valence band of CdTe QDs, further causing an enhanced photocurrent. Thus, on the basis of the dual signal amplification strategy, the competitive immunosensor based on the specific binding of anti-AFP antibodies to AFP and AFP-CdTe-GOx bioconjugates was achieved. This proposed biosensor for AFP possessed largely increased linear detection range from 0.5 pg/mL to 10 μg/mL with a detection limit of 0.13 pg/mL. The proposed amplification strategy shows high sensitivity, stability, and reproducibility and can become a promising platform for other protein detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stoscheck, C. M. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)82008-p · Cited by 1,438
Cited by
Photoelectrochemical bioanalysis: the state of the art
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00228h · Cited by 912
Titanium Dioxide Nanomaterials for Sensor Applications
Bai, J., & Zhou, B. (2014) · Chemical Reviews · doi:10.1021/cr400625j · Cited by 900
Photoelectrochemical DNA Biosensors
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2014) · Chemical Reviews · doi:10.1021/cr500100j · Cited by 857
Catalytic chemistry of glucose oxidase in cancer diagnosis and treatment
Fu, L.-H., Qi, C., Lin, J., & Huang, P. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00891k · Cited by 783
Aptamer-functionalized metal-organic frameworks (MOFs) for biosensing
Lv, M., Zhou, W., Tavakoli, H., Bautista, C., Xia, J., Wang, Z., & Li, X. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112947 · Cited by 331
Construction of Bio‐Piezoelectric Platforms: From Structures and Synthesis to Applications
Xu, Q., Gao, X., Zhao, S., Liu, Y., Zhang, D., Zhou, K., Khanbareh, H., Chen, W., Zhang, Y., & Bowen, C. (2021) · Advanced Materials · doi:10.1002/adma.202008452 · Cited by 298
Devadoss, A., Sudhagar, P., Terashima, C., Nakata, K., & Fujishima, A. (2015) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2015.06.002 · Cited by 298
Metadata
- Authors
- Li, Y.-J., Ma, M.-J., & Zhu, J.-J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-11-20
- Volume
- 84
- Issue
- 23
- Pages
- 10492-10499
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2134449282
- Cited by
- 187
- References
- 1
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.