The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Glutathione-Protected Silver Nanoclusters as Cysteine-Selective Fluorometric and Colorimetric Probe
Abstract
The integration of the unique thiol-Ag chemistry and the specific steric hindrance from the organic layer of fluorescent Ag nanoclusters (AgNCs) was first developed in this work to achieve a simple detection of cysteine (Cys) with high selectivity and sensitivity. The key design is a strongly red-emitting AgNC protected by the interference biothiol, glutathione, or GSH (hereafter referred to as GSH-AgNCs), where both the physicochemical properties (Ag surface chemistry and fluorescence) of the NC core and the physical properties (e.g., steric hindrance) of the organic shell were fully utilized for Cys detection with three major features. First, owing to the specific thiol-Ag interaction, the fluorescent GSH-AgNCs showed superior selectivity for Cys over the other 19 natural amino acids (nonthiol-containing). Second, the GSH protecting layer on the NC surface made possible the differentiation of Cys from GSH (or other large-sized thiol molecules) simply by their size. Third, the ultrasmall size of GSH-AgNCs and the high affinity of the thiol-Ag interaction provided high sensitivity for Cys detection with a detection limit of <3 nM. The assay developed in this study is of interest not only because it provides a simple Cys sensor with high selectivity and sensitivity but also because it exemplifies the utilization of the physical properties of organic ligands on the nanomaterial surface to further improve the sensor performance, which could open a new design strategy for other sensor development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Sub-nanometre sized metal clusters: from synthetic challenges to the unique property discoveries
Lu, Y., & Chen, W. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15325d · Cited by 1,152
Cited by
Atomically Precise Clusters of Noble Metals: Emerging Link between Atoms and Nanoparticles
Chakraborty, I., & Pradeep, T. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00769 · Cited by 2,501
Tailoring the photoluminescence of atomically precise nanoclusters
Kang, X., & Zhu, M. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00800k · Cited by 1,065
Engineering ultrasmall water-soluble gold and silver nanoclusters for biomedical applications
Luo, Z., Zheng, K., & Xie, J. (2014) · Chem. Commun. · doi:10.1039/c3cc47512c · Cited by 441
Self-citationLuminescent Noble Metal Nanoclusters as an Emerging Optical Probe for Sensor Development
Yuan, X., Luo, Z., Yu, Y., Yao, Q., & Xie, J. (2013) · Chemistry – An Asian Journal · doi:10.1002/asia.201201236 · Cited by 328
Self-citation
Metadata
- Authors
- Yuan, X., Tay, Y., Dou, X., Luo, Z., Leong, D. T., & Xie, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-01-11
- Volume
- 85
- Issue
- 3
- Pages
- 1913-1919
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2070486476
- Cited by
- 341
- References
- 2
- FWCI
- 14.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.