The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Real-Time Electrochemical Monitoring of Adenosine Triphosphate in the Picomolar to Micromolar Range Using Graphene-Modified Electrodes
Open accessAbstract
We report on a competitive electrochemical detection system that is free of wash steps and enables the real-time monitoring of adenosine triphosphate (ATP) in a quantitative manner over a five-log concentration range. The system utilizes a recognition surface based on ATP aptamer (ATPA) capture probes prebound to electroactive flavin adenine dinucleotide (FAD) molecules, and a signaling surface utilizing graphene (Gr) and gold nanoparticle (AuNP) modified carbon paste electrode (Gr-AuNP-CPE) that is optimized to enhance electron-transfer kinetics and signal sensitivity. Binding of ATP to ATPA at the recognition surface causes the release of an equivalent concentration of FAD that can be quantitatively monitored in real time at the signaling surface, thereby enabling a wide linear working range (1.14 × 10(-10) to 3.0 × 10(-5) M), a low detection limit (2.01 × 10(-11) M using graphene and AuNP modified glassy carbon), and fast target binding kinetics (steady-state signal within 12 min at detection limit). Unlike assays based on capture probe-immobilized electrodes, this double-surface competitive assay offers the ability to speed up target binding kinetics by increasing the capture probe concentration, with no limitations due to intermolecular Coulombic interactions and nonspecific binding. We utilize the real-time monitoring capability to compute kinetic parameters for target binding and to make quantitative distinctions on degree of base-pair mismatch through monitoring target binding kinetics over a wide concentration range. On the basis of the simplicity of the assay chemistry and the quantitative detection of ATP within fruit and serum media, as demonstrated by comparison of ATP levels against those determined using a standard high-performance liquid chromatography (HPLC)-UV absorbance method, we envision a versatile detection platform for applications requiring real-time monitoring over a wide target concentration range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Cited by
Karimi-Maleh, H., Shojaei, A. F., Tabatabaeian, K., Karimi, F., Shakeri, S., & Moradi, R. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.07.086 · Cited by 293
Adsorptive removal of cadmium(II) ions from liquid phase using acid modified carbon-based adsorbents
Ihsanullah, Al-Khaldi, F. A., Abusharkh, B., Khaled, M., Atieh, M. A., Nasser, M. S., laoui, T., Saleh, T. A., Agarwal, S., Tyagi, I., et al. (2015) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2015.01.033 · Cited by 263
Metadata
- Authors
- Sanghavi, B. J., Sitaula, S., Griep, M. H., Karna, S. P., Ali, M. F., & Swami, N. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-08-12
- Volume
- 85
- Issue
- 17
- Pages
- 8158-8165
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2083747941
- Cited by
- 241
- References
- 1
- FWCI
- 17.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.