Origins of Nanoscale Damage to Glass-Sealed Platinum Electrodes with Submicrometer and Nanometer Size
Open accessThe DOI matches its Crossref record.
Abstract
Glass-sealed Pt electrodes with submicrometer and nanometer size have been successfully developed and applied for nanoscale electrochemical measurements such as scanning electrochemical microscopy (SECM). These small electrodes, however, are difficult to work with because they often lose a current response or give a low SECM feedback in current-distance curves. Here we report that these problems can be due to the nanometer-scale damage that is readily and unknowingly made to the small tips in air by electrostatic discharge or in electrolyte solution by electrochemical etching. The damaged Pt electrodes are recessed and contaminated with removed electrode materials to lower their current responses. The recession and contamination of damaged Pt electrodes are demonstrated by scanning electron microscopy and X-ray energy dispersive spectroscopy. The recessed geometry is noticeable also by SECM but is not obvious from a cyclic voltammogram. Characterization of a damaged Pt electrode with recessed geometry only by cyclic voltammetry may underestimate electrode size from a lower limiting current owing to an invalid assumption of inlaid disk geometry. Significantly, electrostatic damage can be avoided by grounding a Pt electrode and nearby objects, most importantly, an operator as a source of electrostatic charge. Electrochemical damage can be avoided by maintaining potentiostatic control of a Pt electrode without internally disconnecting the electrode from a potentiostat between voltammetric measurements. Damage-free Pt electrodes with submicrometer and nanometer sizes are pivotal for reliable and quantitative nanoelectrochemical measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemistry of Nanoparticles
Kleijn, S. E. F., Lai, S. C. S., Koper, M. T. M., & Unwin, P. R. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201306828 · Cited by 398
Electrochemical Nanoprobes for Single-Cell Analysis
Actis, P., Tokar, S., Clausmeyer, J., Babakinejad, B., Mikhaleva, S., Cornut, R., Takahashi, Y., López Córdoba, A., Novak, P., Shevchuck, A. I., et al. (2014) · ACS Nano · doi:10.1021/nn405612q · Cited by 252
Design of Ru-Ni diatomic sites for efficient alkaline hydrogen oxidation
Han, L., Ou, P., Liu, W., Wang, X., Wang, H.-T., Zhang, R., Pao, C.-W., Liu, X., Pong, W.-F., Song, J., et al. (2022) · Science Advances · doi:10.1126/sciadv.abm3779 · Cited by 229
“Appropriate protection was used to avoid electrostatic damage to the nanotips (44).”
MethodLi, Y., Hu, K., Yu, Y., Rotenberg, S. A., Amatore, C., & Mirkin, M. V. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b06476 · Cited by 215
Kim, J., Renault, C., Nioradze, N., Arroyo-Currás, N., Leonard, K. C., & Bard, A. J. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b03980 · Cited by 171
Self-citation
Metadata
- Authors
- Nioradze, N., Chen, R., Kim, J., Shen, M., Santhosh, P., & Amemiya, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-06-13
- Volume
- 85
- Issue
- 13
- Pages
- 6198-6202
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2015580438
- Cited by
- 120
- References
- 0
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Origins of Nanoscale Damage to Glass-Sealed Platinum Electrodes with Submicrometer and Nanometer Size. https://app.cochat.ai/papers/10.1021/ac401316n
- The paper
- Nioradze, N., Chen, R., Kim, J., Shen, M., Santhosh, P., & Amemiya, S. (2013). Origins of Nanoscale Damage to Glass-Sealed Platinum Electrodes with Submicrometer and Nanometer Size. Analytical Chemistry. https://doi.org/10.1021/ac401316n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.