The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Electrochemical Sensing and Biosensing Platform Based on Biomass-Derived Macroporous Carbon Materials
Abstract
A three-dimensional (3D) macroporous carbon (3D-KSCs) derived from kenaf stem (KS) is proposed as a novel supporting material for electrochemical sensing and a biosensing platform. A series of 3D-KSCs/inorganic nanocomposites such as Prussian blue (PB) nanoparticles (NPs)-carboxylic group-functionalized 3D-KSCs (PBNPs-3D-FKSCs), CuNiNPs-3D-KSCs, and CoNPs-3D-KSCs were prepared by a facile two-step route consisting of carbonization and subsequent chemical synthesis or one-step carbonization of KS-metal ion complex. The obtained 3D-KSCs/inorganic nanocomposites were characterized by X-ray diffraction, X-ray photoelectron spectroscopy, energy dispersive X-ray spectroscopy, scanning electron microscopy, and Fourier transform-infrared spectroscopy. A whole piece of 3D-KSCs/nanocomposites was used to prepare an integrated 3D-KSCs/nanocomposite electrode. Compared to the electrode modified by graphene, carbon nanotubes and their derivatives, which can form close-packed structure after assembled on electrode surface, the integrated 3D-KSCs/nanocomposite electrode shows a 3D honeycomb porous structure. Such structure provides a large specific surface area, effectively supports a large number of electro-active species, and greatly enhances the mass and electron transfer. The electrochemical behaviors and electrocatalytic performances of the integrated 3D-KSCs/inorganic nanocomposite electrode were evaluated by cyclic voltammetry and the amperometric method. The resulted PBNPs-3D-FKSCs, CuNiNPs-3D-KSCs, and CoNPs-3D-KSCs electrode show good electrocatalytic performances toward the reduction of H2O2, the oxidation of glucose and amino acid, respectively. Therefore, the low-cost, renewable, and environmentally friendly 3D-KSCs should be promising supporting materials for an electrochemical sensor and biosensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Sustainable porous carbons with a superior performance for CO2 capture
Sevilla, M., & Fuertes, A. B. (2011) · Energy & Environmental Science · doi:10.1039/c0ee00784f · Cited by 1,088
Cited by
Hierarchically porous carbon by activation of shiitake mushroom for capacitive energy storage
Cheng, P., Gao, S., Zang, P., Yang, X., Bai, Y., Xu, H., Liu, Z., & Lei, Z. (2015) · Carbon · doi:10.1016/j.carbon.2015.05.056 · Cited by 429
Nanomaterials based electrochemical sensor and biosensor platforms for environmental applications
Maduraiveeran, G., & Jin, W. (2017) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2017.02.001 · Cited by 398
Review—Nanostructured Materials-Based Nanosensors
Abdel-Karim, R., Reda, Y., & Abdel-Fattah, A. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67aa · Cited by 303
Metadata
- Authors
- Wang, L., Zhang, Q., Chen, S., Xu, F., Chen, S., Jia, J., Tan, H., Hou, H., & Song, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-01-22
- Volume
- 86
- Issue
- 3
- Pages
- 1414-1421
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2321373640
- Cited by
- 225
- References
- 2
- FWCI
- 13.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.