The ability to study organisms by direct analysis of their proteomes without digestion via mass spectrometry has benefited greatly from recent advances in separation techniques, instrumentation, and bioinformatics. However, improvements to data acquisition logic have lagged in comparison. Past workflows for Top Down Proteomics (TDPs) have focused on high throughput at the expense of maximal protein coverage and characterization. This mode of data acquisition has led to enormous overlap in the identification of highly abundant proteins in subsequent LC-MS injections. Furthermore, a wealth of data is left underutilized by analyzing each newly targeted species as unique, rather than as part of a collection of fragmentation events on a distinct proteoform. Here, we present a major advance in software for acquisition of TDP data that incorporates a fully automated workflow able to detect intact masses, guide fragmentation to achieve maximal identification and characterization of intact protein species, and perform database search online to yield real-time protein identifications. On Pseudomonas aeruginosa, the software combines fragmentation events of the same precursor with previously obtained fragments to achieve improved characterization of the target form by an average of 42 orders of magnitude in confidence. When HCD fragmentation optimization was applied to intact proteins ions, there was an 18.5 order of magnitude gain in confidence. These improved metrics set the stage for increased proteome coverage and characterization of higher order organisms in the future for sharply improved control over MS instruments in a project- and lab-wide context.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac402904h

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 35

Metadata

Authors
Durbin, K. R., Fellers, R. T., Ntai, I., Kelleher, N. L., & Compton, P. D.
Venue
Analytical Chemistry
Published
2014-01-23
Volume
86
Issue
3
Pages
1485-1492
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2078746221
Cited by
35
References
5
FWCI
2.45
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Autopilot: An Online Data Acquisition Control System for the Enhanced High-Throughput Characterization of Intact Proteins. https://app.cochat.ai/papers/10.1021/ac402904h
The paper
Durbin, K. R., Fellers, R. T., Ntai, I., Kelleher, N. L., & Compton, P. D. (2014). Autopilot: An Online Data Acquisition Control System for the Enhanced High-Throughput Characterization of Intact Proteins. Analytical Chemistry. https://doi.org/10.1021/ac402904h

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.