The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Turn-on Persistent Luminescence Probe Based on Graphitic Carbon Nitride for Imaging Detection of Biothiols in Biological Fluids
Abstract
Herein, we present a novel strategy based on a "turn-on" persistent luminescence imaging chemical system of graphitic carbon nitride for detecting biothiols in biological fluids. Graphitic carbon nitride (g-C3N4) as persistent luminescence probe is fabricated via a new procedure based on pyrolysis of guanidine hydrochloride under ambient atmospheric conditions. The prepared g-C3N4 nanosheets give intensively long-persistent luminescence that can avoid interference from biological media such as tissue autofluorescence and scattering light. The original persistent luminescence of g-C3N4 turns off due to the adsorption of silver ion (Ag(+)) onto g-C3N4 materials with an electron transfer process. The presence of biothiols induces the onset of persistent luminescence emission by interrupting the quenching interaction, thereby turning on the imaging probe. The approach exhibits high specificity and high sensitivity to biothiols with low detection limit for cysteine (Cys), homocysteine (Hcy), and glutathione (GSH) with 6.4, 8.1, and 9.6 nM, respectively. It is also successfully applied for imaging detection of biothiols in human urine, plasma, and cell lysates, demonstrating its great value of practical application in biological systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Cited by
Long persistent phosphors—from fundamentals to applications
Li, Y., Gecevicius, M., & Qiu, J. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00582e · Cited by 1,368
Graphitic carbon nitride “reloaded”: emerging applications beyond (photo)catalysis
Liu, J., Wang, H., & Antonietti, M. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00767d · Cited by 930
Wang, A., Wang, C., Fu, L., Wong-Ng, W., & Lan, Y. (2017) · Nano-Micro Letters · doi:10.1007/s40820-017-0148-2 · Cited by 498
Molecular Probes for Autofluorescence-Free Optical Imaging
Jiang, Y., & Pu, K. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00506 · Cited by 426
Bright-Yellow-Emissive N-Doped Carbon Dots: Preparation, Cellular Imaging, and Bifunctional Sensing
Jiang, K., Sun, S., Zhang, L., Wang, Y., Cai, C., & Lin, H. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b07255 · Cited by 395
Metadata
- Authors
- Tang, Y., Song, H., Su, Y., & Lv, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-11-27
- Volume
- 85
- Issue
- 24
- Pages
- 11876-11884
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1989528917
- Cited by
- 219
- References
- 1
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Turn-on Persistent Luminescence Probe Based on Graphitic Carbon Nitride for Imaging Detection of Biothiols in Biological Fluids. https://app.cochat.ai/papers/10.1021/ac403517u
- The paper
- Tang, Y., Song, H., Su, Y., & Lv, Y. (2013). Turn-on Persistent Luminescence Probe Based on Graphitic Carbon Nitride for Imaging Detection of Biothiols in Biological Fluids. Analytical Chemistry. https://doi.org/10.1021/ac403517u
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.