Quality Control for Building Libraries from Electrospray Ionization Tandem Mass Spectra
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Electrospray ionization (ESI) tandem mass spectrometry coupled with liquid chromatography is a routine technique for identifying and quantifying compounds in complex mixtures. The identification step can be aided by matching acquired tandem mass spectra (MS(2)) against reference library spectra as is routine for electron ionization (EI) spectra from gas chromatography/mass spectrometry (GC/MS). However, unlike the latter spectra, ESI MS(2) spectra are likely to originate from various precursor ions for a given target molecule and may be acquired at varying energies and resolutions and have characteristic noise signatures, requiring processing methods very different from EI to obtain complete and high quality reference spectra for individual analytes. This paper presents procedures developed for creating a tandem mass spectral library that addresses these factors. Library building begins by acquiring MS(2) spectra for all major MS(1) peaks in an infusion run, followed by assigning MS(2) spectra to clusters and creating a consensus spectrum for each. Intensity-based constraints for cluster membership were developed, as well as peak testing to recognize and eliminate suspect peaks and reduce noise. Consensus spectra were then examined by a human evaluator using a number of criteria, including a fraction of annotated peaks and consistency of spectra for a given ion at different energies. These methods have been developed and used to build a library from >9000 compounds, yielding 230,000 spectra.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kind, T., & Fiehn, O. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-105 · Cited by 1,201
Lam, H., Deutsch, E. W., Eddes, J. S., Eng, J. K., King, N., Stein, S. E., & Aebersold, R. (2007) · PROTEOMICS · doi:10.1002/pmic.200600625 · Cited by 517
Self-citation
Cited by
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
Vinaixa, M., Schymanski, E. L., Neumann, S., Navarro, M., Salek, R. M., & Yanes, O. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.09.005 · Cited by 562
Identification of small molecules using accurate mass MS/MS search
Kind, T., Tsugawa, H., Cajka, T., Ma, Y., Lai, Z., Mehta, S. S., Wohlgemuth, G., Barupal, D. K., Showalter, M. R., Arita, M., et al. (2018) · Mass Spectrometry Reviews · doi:10.1002/mas.21535 · Cited by 479
Metabolic reaction network-based recursive metabolite annotation for untargeted metabolomics
Shen, X., Wang, R., Xiong, X., Yin, Y., Cai, Y., Ma, Z., Liu, N., & Zhu, Z.-J. (2019) · Nature Communications · doi:10.1038/s41467-019-09550-x · Cited by 364
Zhou, Z., Luo, M., Zhang, H., Yin, Y., Cai, Y., & Zhu, Z.-J. (2022) · Nature Communications · doi:10.1038/s41467-022-34537-6 · Cited by 339
Metadata
- Authors
- Yang, X., Neta, P., & Stein, S. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-06-13
- Volume
- 86
- Issue
- 13
- Pages
- 6393-6400
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2330835577
- Cited by
- 86
- References
- 2
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality Control for Building Libraries from Electrospray Ionization Tandem Mass Spectra. https://app.cochat.ai/papers/10.1021/ac500711m
- The paper
- Yang, X., Neta, P., & Stein, S. E. (2014). Quality Control for Building Libraries from Electrospray Ionization Tandem Mass Spectra. Analytical Chemistry. https://doi.org/10.1021/ac500711m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.