The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Highly Sensitive Graphene–Pt Nanocomposites Amperometric Biosensor and Its Application in Living Cell H2O2Detection
Abstract
A sensitive hydrogen peroxide (H2O2) sensor was constructed based on graphene-Pt (RGO-Pt) nanocomposites and used to measure the release of H2O2 from living cells. The graphene and Pt nanoparticles (Pt NPs) were modified on glassy carbon electrode (GCE) by the physical adsorption and electrodeposition of K2PtCl6 solution, respectively. Through characterization by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS), it was observed that the electrodeposited Pt NPs were densely covered and well distributed on the entire graphene surface. Electrochemical study demonstrates that the RGO-Pt nanocomposites modified glassy carbon electrode exhibited a high peak current and low overpotential toward the reduction of H2O2. The relevant detection limit of H2O2 is ∼0.2 μM with a wide linear range from 0.5 μM to 3.475 mM, displaying a much higher sensitivity (459 ± 3 mA M(-1) cm(-2), n = 5) than that of Pt nanoparticles or graphene modified electrode. This novel biosensor can measure the H2O2 release from living cells because of its low detection limit, wide linear range, and higher sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeting cancer cells by ROS-mediated mechanisms: a radical therapeutic approach?
Trachootham, D., Alexandre, J., & Huang, P. (2009) · Nature Reviews Drug Discovery · doi:10.1038/nrd2803 · Cited by 5,452
H 2 O 2 , a Necessary Evil for Cell Signaling
Rhee, S. G. (2006) · Science · doi:10.1126/science.1130481 · Cited by 2,160
Graphene-based nanomaterials and their electrochemistry
Pumera, M. (2010) · Chemical Society Reviews · doi:10.1039/c002690p · Cited by 1,117
Chen, Q., Espey, M. G., Krishna, M. C., Mitchell, J. B., Corpe, C. P., Buettner, G. R., Shacter, E., & Levine, M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0506390102 · Cited by 1,075
Cited by
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Metal–Organic Framework-Based Sensors for Environmental Contaminant Sensing
Fang, X., Zong, B., & Mao, S. (2018) · Nano-Micro Letters · doi:10.1007/s40820-018-0218-0 · Cited by 576
Carbon nanomaterial-based electrochemical biosensors: an overview
Wang, Z., & Dai, Z. (2015) · Nanoscale · doi:10.1039/c5nr00585j · Cited by 427
Xu, J., Wang, Y., & Hu, S. (2017) · Microchimica Acta · doi:10.1007/s00604-016-2007-0 · Cited by 405
Zhang, R., & Chen, W. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.01.080 · Cited by 368
Metadata
- Authors
- Zhang, Y., Bai, X., Wang, X., Shiu, K.-K., Zhu, Y., & Jiang, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-09-15
- Volume
- 86
- Issue
- 19
- Pages
- 9459-9465
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2321785376
- Cited by
- 297
- References
- 4
- FWCI
- 15.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.