Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 217

The DOI matches its Crossref record.

A Method Detection Limit for the Analysis of Natural Organic Matter via Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Riedel, Thomas, Dittmar, Thorsten · 2014 · Analytical Chemistry

Abstract

Fourier Transform Ion Cyclotron Resonance mass spectra (FT-ICR-MS) of natural organic matter are complex and consist of several thousands of peaks. The corresponding mass to charge ratios (m/z) and signal intensities result from analytes and noise. The most commonly applied way of distinguishing between analyte and noise is a fixed signal-to-noise ratio below which a detected peak is considered noise. However, this procedure is problematic and can yield ambiguous results. For example, random noise peaks can occur slightly above the signal-to-noise threshold (false positives), while peaks of low abundance analytes may occasionally fall below the fixed threshold (false negatives). Thus, cumulative results from repeated measurements of the same sample contain more peaks than a single measurement. False positive and false negative signals are difficult to distinguish, which affects the reproducibility between replicates of a sample. To target this issue, we tested the feasibility of a method detection limit (MDL) for the analysis of natural organic matter to identify peaks that can reliably be distinguished from noise by estimating the uncertainty of the noise. We performed 556 replicate analyses of a dissolved organic matter sample from the deep North Pacific on a 15 T FT-ICR-MS; each of these replicate runs consisted of 500 cumulated broadband scans. To unambiguously identify analyte peaks in the mass spectra, the sample was also run at time-consuming high-sensitivity settings. The resulting data set was used to establish and thoroughly test a MDL. The new method is easy to establish with software help, does only require the additional analysis of replicate blanks (low time increase), and can implement all steps of sample preparation. Especially when analysis time does not allow for replicate runs, major merits of the MDL are reliable removal of false positive (noise) peaks and better reproducibility, while the risk of losing analytes with low signal intensities (false negative) is comparatively low. When replicate analyses are feasible, the removal of all singly detected peaks is further recommended, as these have the highest probability of being noise peaks. We suggest that the here proposed detection limit should become routine in FT-ICR-MS data processing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac501946m

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Riedel, T., & Dittmar, T.
Venue
Analytical Chemistry
Published
2014-08-06
Volume
86
Issue
16
Pages
8376-8382
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2325339159
Cited by
217
References
0
FWCI
4.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.